573 1154

Cited 0 times in

종합병원의 실내공기에 분포하는 부유 세균과 진균의 입경별 종류와 특성

DC Field Value Language
dc.contributor.author노재훈-
dc.contributor.author원종욱-
dc.date.accessioned2015-06-10T12:06:46Z-
dc.date.available2015-06-10T12:06:46Z-
dc.date.issued2006-
dc.identifier.issn1226-4326-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/109212-
dc.description.abstractThe objective of this study is to provide fundamental data for pertinent management of indoor air quality through investigating the size-based characteristics of bioaerosol distributed in the general hospital. Measurement sites are main lobby, ICU, ward and laboratory and total five times were sampled with six-stage cascade impactor. Based on the result of this study, concentrations of airborne bacteria and fungi were the highest in main lobby as followed by an order of ward, ICU and laboratory. Concentrations of airborne bacteria was generally higher than those of airborne fungi and the ratio of indoor and outdoor concentration of both exceeded 1.0 in all the measurement sites of the general hospital. The predominant genera of airborne bacteria identified in the general hospital were Staphylococcus spp.(50%), Micrococcus spp.(15-20%), Corynebacterium spp.(5-20%), and Bacillus spp.(5-15%). On the other hand, the predominant genera of airborne fungi identified in the general hospital were Cladosporium spp.(30%), Penicillium spp.(20-25%), Aspergillus spp.(15-20%), and Alternaria spp.(10-20%). In regard to size distribution of bioaerosol, the detection rate was generally highest on 5 stage(1.1 2.1㎛) for airborne bacteria and on 1 stage(>7.0㎛) for airborne fungi. Cleanliness of facilities in the general hospital and condition of HVAC system should be monitored regularly to prevent indoor air contamination by airborne microorganisms.-
dc.description.statementOfResponsibilityopen-
dc.format.extent101~109-
dc.relation.isPartOfJournal of Korean Society of Occupational and Environmental Hygiene (한국산업위생학회지)-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.title종합병원의 실내공기에 분포하는 부유 세균과 진균의 입경별 종류와 특성-
dc.title.alternativeSize-based characteristics of airborne bacteria and fungi distributed in the general hospital-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Preventive Medicine (예방의학)-
dc.contributor.googleauthor김기연-
dc.contributor.googleauthor이창래-
dc.contributor.googleauthor김치년-
dc.contributor.googleauthor원종욱-
dc.contributor.googleauthor노재훈-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA01294-
dc.contributor.localIdA02442-
dc.relation.journalcodeJ03170-
dc.subject.keywordgeneral hospital-
dc.subject.keywordairborne bacteria-
dc.subject.keywordairbornefungi-
dc.subject.keywordsize distribution-
dc.subject.keywordbioaerosol-
dc.contributor.alternativeNameRoh, Jae Hoon-
dc.contributor.alternativeNameWon, Jong Uk-
dc.contributor.affiliatedAuthorRoh, Jae Hoon-
dc.contributor.affiliatedAuthorWon, Jong Uk-
dc.rights.accessRightsfree-
dc.citation.volume16-
dc.citation.number2-
dc.citation.startPage101-
dc.citation.endPage109-
dc.identifier.bibliographicCitationJournal of Korean Society of Occupational and Environmental Hygiene (한국산업위생학회지), Vol.16(2) : 101-109, 2006-
dc.identifier.rimsid55762-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Occupational and Environmental Medicine (작업환경의학과) > 1. Journal Papers
1. College of Medicine (의과대학) > Dept. of Preventive Medicine (예방의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.