474 576

Cited 0 times in

복합 레진의 간헐적 광중합 방법이 중합 수축 속도와 치아의 교두 변위에 미치는 영향

Other Titles
 Effect of intermittent polymerization on the rate of polymerization shrinkage and cuspal deflection in composite resin 
Authors
 김민경  ;  박성호  ;  서덕규  ;  송윤정  ;  이 윤  ;  이찬영 
Citation
 Journal of Korean Academy of Operative Dentistry (대한치과보존학회지), Vol.33(4) : 341-351, 2008 
Journal Title
Journal of Korean Academy of Operative Dentistry(대한치과보존학회지)
ISSN
 1225-0864 
Issue Date
2008
Keywords
Intermittent polymerization ; Rate of polymerization shrinkage ; Cuspal deflection ; Composite resin
Abstract
This study investigated the effect of intermittent polymerization on the rate of polymerization shrinkage and cuspal deflection in composite resins. The linear polymerization shrinkage of each composite was measured using the custom-made linometer along with the light shutter specially devised to block the light at the previously determined interval. Samples were divided into 4 groups by light curing method; Group 1) continuous light (60s with light on); Group 2) intermittent light (cycles of 3s with 2s light on & 1s with light off for 90s); Group 3) intermittent light (cycles of 2s with 1s light on & 1s with light off for 120s); Group 4) intermittent light (cycles of 3s with 1s light on & 2s with light off for 180s). The amount of linear polymerization shrinkage was measured and its maximum rate (Rmax) and peak time (PT) in the first 15 seconds were calculated. For the measurement of cuspal deflection of teeth, MOD cavities were prepared in 10 extracted maxillary premolars. Reduction in the intercuspal distance was measured by the custom-made cuspal deflection measuring machine. ANOVA analysis was used for the comparison of the light curing groups and t-test was used to determine significant difference between the composite resins. Pyramid showed the greater amount of polymerization shrinkage than Heliomolar (p < 0.05). There was no significant difference in the linear polymerization shrinkage among the groups. The Rmax was group 4 < 3, 2 < 1 in Heliomolar and group 3 < 4 < 2, 1 in Pyramid (p < 0.05). Pyramid demonstrated greater cuspal deflection than Heliomolar. The cuspal deflection in Heliomolar was group 4 < 3 < 2, 1 and group 4, 3 < 2, 1 in Pyramid (p < 0.05). It was concluded that the reduced rate of polymerization shrinkage by intermittent polymerization can help to decrease the cuspal deflection.
Files in This Item:
T200803133.pdf Download
DOI
10.5395/JKACD.2008.33.4.341
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Conservative Dentistry (보존과학교실) > 1. Journal Papers
Yonsei Authors
Park, Sung Ho(박성호) ORCID logo https://orcid.org/0000-0003-2171-235X
Seo, Deog Gyu(서덕규)
Lee, Chan Young(이찬영)
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/108067
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links