561 677

Cited 0 times in

사지에 발병한 카포시육종의 방사선치료를 위한 물볼루스 기구의 유용성 고찰

DC Field Value Language
dc.contributor.author김용배-
dc.contributor.author서창옥-
dc.contributor.author이익재-
dc.contributor.author조재호-
dc.date.accessioned2015-05-19T16:59:14Z-
dc.date.available2015-05-19T16:59:14Z-
dc.date.issued2008-
dc.identifier.issn1229-8719-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/107314-
dc.description.abstractPurpose: We designed a water-based bolus device for radiation therapy in Kaposi's sarcoma. This study evaluated the usefulness of this new device and compared it with the currently used rice-based bolus. Materials and Methods: We fashioned a polystyrene box and cut a hole in order to insert patient's extremities while the patient was in the supine position. We used a vacuum-vinyl based polymer to reduce water leakage. Next, we eliminated air using a vacuum pump and a vacuum valve to reduce the air gap between the water and extremities in the vacuum-vinyl box. We performed CT scans to evaluate the density difference of the fabricated water-based bolus device when the device in which the rice-based bolus was placed directly, the rice-based bolus with polymer-vinyl packed rice, and the water were all put in. We analyzed the density change with the air gap volume using a planning system. In addition, we measured the homogeneity and dose in the low-extremities phantom, attached to six TLD, and wrapped film exposed in parallel-opposite fields with the LINAC under the same conditions as the set-up of the CT-simulator. Results: The density value of the rice-based bolus with the rice put in directly was 14% lower than that of the water-based bolus. Moreover, the value of the other experiments in the rice-based bolus with the polymer-vinyl packed rice showed an 18% reduction in density. The analysis of the EDR2 film revealed that the water-based bolus shows a more homogeneous dose plan, which was superior by $4{\sim}4.4%$ to the rice-base bolus. The mean TLD readings of the rice-based bolus, with the rice put directly into the polystyrene box had a 3.4% higher density value. Moreover, the density value in the case of the rice-based bolus with polymer-vinyl packed rice had a 4.3% higher reading compared to the water-based bolus. Conclusion: Our custom-made water-based bolus device increases the accuracy of the set-up by confirming the treatment field. It also improves the accuracy of the therapy owing to the reduction of the air gap using a vacuum pump and a vacuum valve. This set-up represents a promising alternative device for delivering a homogenous dose to the target volume-
dc.description.statementOfResponsibilityopen-
dc.format.extent189~194-
dc.languageKorean-
dc.publisher대한방사선종양학회-
dc.relation.isPartOfJournal of the Korean Society for Therapeutic Radiology and Oncology-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.title사지에 발병한 카포시육종의 방사선치료를 위한 물볼루스 기구의 유용성 고찰-
dc.title.alternativeEvaluation of a Water-based Bolus Device for Radiotherapy to the Extremities in Kaposi's Sarcoma Patients-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Radiation Oncology (방사선종양학)-
dc.contributor.googleauthor안승권-
dc.contributor.googleauthor김용배-
dc.contributor.googleauthor이익재-
dc.contributor.googleauthor송태수-
dc.contributor.googleauthor손동민-
dc.contributor.googleauthor장영재-
dc.contributor.googleauthor조정희-
dc.contributor.googleauthor김주호-
dc.contributor.googleauthor김동욱-
dc.contributor.googleauthor조재호-
dc.contributor.googleauthor서창옥-
dc.identifier.doi10.3857/jkstro.2008.26.3.189-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA03901-
dc.contributor.localIdA00744-
dc.contributor.localIdA01919-
dc.contributor.localIdA03055-
dc.relation.journalcodeJ01857-
dc.identifier.pmidKaposi's sarcoma ; Water-based bolus ; Rice-based bolus-
dc.subject.keywordKaposi's sarcoma-
dc.subject.keywordWater-based bolus-
dc.subject.keywordRice-based bolus-
dc.contributor.alternativeNameKim, Yong Bae-
dc.contributor.alternativeNameSuh, Chang Ok-
dc.contributor.alternativeNameLee, Ik Jae-
dc.contributor.alternativeNameCho, Jae Ho-
dc.contributor.affiliatedAuthorCho, Jae Ho-
dc.contributor.affiliatedAuthorKim, Yong Bae-
dc.contributor.affiliatedAuthorSuh, Chang Ok-
dc.contributor.affiliatedAuthorLee, Ik Jae-
dc.rights.accessRightsfree-
dc.citation.volume26-
dc.citation.number3-
dc.citation.startPage189-
dc.citation.endPage194-
dc.identifier.bibliographicCitationJournal of the Korean Society for Therapeutic Radiology and Oncology, Vol.26(3) : 189-194, 2008-
dc.identifier.rimsid48283-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiation Oncology (방사선종양학교실) > 1. Journal Papers

qrcode