Cited 12 times in
Intravascular ultrasound evaluation of optimal drug-eluting stent expansion after poststent balloon dilation using a noncompliant balloon versus a semicompliant balloon (from the Poststent Optimal Stent Expansion Trial [POET]).
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 장양수 | - |
dc.contributor.author | 최동훈 | - |
dc.contributor.author | 고영국 | - |
dc.contributor.author | 김중선 | - |
dc.date.accessioned | 2015-05-19T16:23:51Z | - |
dc.date.available | 2015-05-19T16:23:51Z | - |
dc.date.issued | 2008 | - |
dc.identifier.issn | 0002-9149 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/106231 | - |
dc.description.abstract | The impact of type of balloon such as noncompliant (NC; Quantum) or semicompliant (SC; Maverick(2)) used after stent dilation on optimal stent expansion (OSE) has not been established for drug-eluting stents (DESs). We conducted a prospective multicenter, randomized study to compare NC with SC balloons after stent balloon dilatation. A total of 301 patients (127 men, 83 women, 62 +/- 9 years of age) treated with a DES (sirolimus-eluting stent [SES], n = 152; paclitaxel-eluting stent, n = 149) were included. OSE followed the definition of the Multicenter Ultrasound Stenting in Coronaries (MUSIC) study. The primary end point was the incidence of OSE using intravascular ultrasound according to type of balloon. Baseline characteristics of each group showed no significant differences. OSE in the SC balloon group was achieved at higher rates than the NC balloon group (53 +/- 35%, vs 73 +/- 48%, p = 0.022 in all stents; 25 +/- 33%, vs 36, 48%, p = 0.051 in SESs). However, any differences in the achievement of OSE between the NC and SC balloon groups were not present in paclitaxel-eluting stents. In conclusion, despite postadjuvant balloon inflations with high pressures, underexpansion of the DES was seen commonly. Between the 2 types of balloon for adjuvant dilation after DES implantation, same-size SC balloons could be more useful for obtaining OSE than NC balloons, especially in SESs. | - |
dc.description.statementOfResponsibility | open | - |
dc.format.extent | 304~310 | - |
dc.relation.isPartOf | AMERICAN JOURNAL OF CARDIOLOGY | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.subject.MESH | Angioplasty, Balloon, Coronary/instrumentation* | - |
dc.subject.MESH | Coronary Vessels/diagnostic imaging | - |
dc.subject.MESH | Drug-Eluting Stents* | - |
dc.subject.MESH | Female | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Male | - |
dc.subject.MESH | Middle Aged | - |
dc.subject.MESH | Paclitaxel/administration & dosage | - |
dc.subject.MESH | Prospective Studies | - |
dc.subject.MESH | Sirolimus/administration & dosage | - |
dc.subject.MESH | Ultrasonography, Interventional* | - |
dc.title | Intravascular ultrasound evaluation of optimal drug-eluting stent expansion after poststent balloon dilation using a noncompliant balloon versus a semicompliant balloon (from the Poststent Optimal Stent Expansion Trial [POET]). | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Internal Medicine (내과학) | - |
dc.contributor.googleauthor | Jung-Sun Kim | - |
dc.contributor.googleauthor | Jae-Youn Moon | - |
dc.contributor.googleauthor | Young-Guk Ko | - |
dc.contributor.googleauthor | Donghoon Choi | - |
dc.contributor.googleauthor | Yangsoo Jang | - |
dc.contributor.googleauthor | Woong Chol Kang | - |
dc.contributor.googleauthor | Taehoon Ahn | - |
dc.contributor.googleauthor | Byoung-Keuk Kim | - |
dc.contributor.googleauthor | Seong Jin Oh | - |
dc.contributor.googleauthor | Dong Woon Jeon | - |
dc.contributor.googleauthor | Joo-Young Yang | - |
dc.identifier.doi | 10.1016/j.amjcard.2008.03.059 | - |
dc.admin.author | false | - |
dc.admin.mapping | false | - |
dc.contributor.localId | A03448 | - |
dc.contributor.localId | A04053 | - |
dc.contributor.localId | A00127 | - |
dc.contributor.localId | A00961 | - |
dc.relation.journalcode | J00071 | - |
dc.identifier.eissn | 1879-1913 | - |
dc.identifier.pmid | 18638591 | - |
dc.identifier.url | http://www.sciencedirect.com/science/article/pii/S0002914908005742 | - |
dc.subject.keyword | Angioplasty, Balloon, Coronary/instrumentation* | - |
dc.subject.keyword | Coronary Vessels/diagnostic imaging | - |
dc.subject.keyword | Drug-Eluting Stents* | - |
dc.subject.keyword | Female | - |
dc.subject.keyword | Humans | - |
dc.subject.keyword | Male | - |
dc.subject.keyword | Middle Aged | - |
dc.subject.keyword | Paclitaxel/administration & dosage | - |
dc.subject.keyword | Prospective Studies | - |
dc.subject.keyword | Sirolimus/administration & dosage | - |
dc.subject.keyword | Ultrasonography, Interventional* | - |
dc.contributor.alternativeName | Jang, Yang Soo | - |
dc.contributor.alternativeName | Choi, Dong Hoon | - |
dc.contributor.alternativeName | Ko, Young Guk | - |
dc.contributor.alternativeName | Kim, Jung Sun | - |
dc.contributor.affiliatedAuthor | Jang, Yang Soo | - |
dc.contributor.affiliatedAuthor | Choi, Dong Hoon | - |
dc.contributor.affiliatedAuthor | Ko, Young Guk | - |
dc.contributor.affiliatedAuthor | Kim, Jung Sun | - |
dc.rights.accessRights | not free | - |
dc.citation.volume | 102 | - |
dc.citation.number | 3 | - |
dc.citation.startPage | 304 | - |
dc.citation.endPage | 310 | - |
dc.identifier.bibliographicCitation | AMERICAN JOURNAL OF CARDIOLOGY, Vol.102(3) : 304-310, 2008 | - |
dc.identifier.rimsid | 56294 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.