782 995

Cited 0 times in

샤임플러그 사진기와 초음파 생체현미경을 이용한 전방 계측 비교

Other Titles
 Comparison of Measurement of Anterior Segment Parameters Between Scheimpflug Camera and Ultrasound Biomicroscopy 
Authors
 박용식  ;  안현석  ;  김나래  ;  마경탁  ;  홍사민  ;  성공제  ;  김찬윤 
Citation
 JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, Vol.50(12) : 1847-1852, 2009 
Journal Title
JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY(대한안과학회지)
ISSN
 0378-6471 
Issue Date
2009
Keywords
Anterior chamber angle ; Anterior chamber depth ; Pentacam ; Primary angle-closure glaucoma (PACG) ; Ultrasound biomicroscope (UBM)
Abstract
Purpose: To evaluate the clinical reliability of PentacamⓇ by comparing anterior chamber parameters measured by Oculus Pentacam system (Oculus Inc., Germany) and Hi-scan ultrasound biomicroscopy (OPTIKON 2000, Rome, Italy) in primary angle closure (PAC) and normal patients. Methods: A prospective study was performed from June 2006 to January 2007. Fifty-one eyes in 26 primary angle-closure patients and 39 eyes in 20 normal control patients, for a total of 90 eyes of 46 patients were recruited from glaucoma out-patient clinics. The correlation and agreement of both measurements of anterior chamber depth and anterior chamber angle measured by UBM and PentacamⓇ were calculated. Sensitivity and specificity of each tool were also compared and the diagnostic value of angle closure was examined. Results: Anterior chamber depth measured by UBM and PentacamⓇ showed strong correlation in the normal control group (r=0.821) and PAC group (r=0.957). Anterior chamber angle showed moderate correlation in the normal control group (r=0.523) and PAC group (r=0.456) while good agreement was also observed. In diagnosing angle closure, anterior chamber measurements appear similar in UBM and PentacamⓇ using the ROC curve (AUC of UBM, 0.942; AUC of PentacamⓇ, 0.931). Conclusions: PentacamⓇ shows high to moderate correlation of anterior chamber measurements and good agreement compared with UBM. PentacamⓇ shows similar ability in diagnosing angle closure compared with UBM and thus is expected to be a good tool in diagnosing angle closure
Files in This Item:
T200904896.pdf Download
DOI
10.3341/jkos.2009.50.12.1847
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Ophthalmology (안과학교실) > 1. Journal Papers
Yonsei Authors
Kim, Na Rae(김나래)
Kim, Chan Yun(김찬윤) ORCID logo https://orcid.org/0000-0002-8373-9999
Seong, Gong Je(성공제) ORCID logo https://orcid.org/0000-0002-5456-4296
Ahn, Hyun Seok(안현석)
Hong, Sa Min(홍사민)
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/105550
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links