384 715

Cited 10 times in

The change of rotational freedom following different insertion torques in three implant systems with implant driver.

DC Field Value Language
dc.contributor.author권주현-
dc.contributor.author김선재-
dc.contributor.author장재승-
dc.contributor.author한종현-
dc.date.accessioned2015-04-24T17:14:32Z-
dc.date.available2015-04-24T17:14:32Z-
dc.date.issued2009-
dc.identifier.issn2005-7806-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/105023-
dc.description.abstractSTATEMENT OF PROBLEM: Implant drivers are getting popular in clinical dentistry. Unlike to implant systems with external hex connection, implant drivers directly engage the implant/abutment interface. The deformation of the implant/abutment interface can be introduced while placing an implant with its implant driver in clinical situations. PURPOSE: This study evaluated the change of rotational freedom between an implant and its abutment after application of different insertion torques. MATERIAL AND METHODS: Three kinds of internal connection implants were utilized for the current study (4.5 × 12 mm Xive, 4.3 × 11.5 mm Inplant Magicgrip, 4.3 × 12 mm Implantium MF). An EstheticBase, a 2-piece top, a Dual abutment was used for its corresponding implant system. The rotational freedom between an implant and its abutment were measured before and after applying 45, 100 Ncm insertion torque. Repeated measures ANOVA was used for statistical analysis. RESULTS: Under 45 Ncm insertion torque, the rotational freedom between an implant and its abutment was significantly increased in Xive (P = .003). However, no significant change was noted in Inplant Magicgrip and Implantium MF. Under 100 Ncm torque, both in Xive (P = .0005) and Implatium MF (P = .03) resulted in significantly increased rotational freedom between the implant and its abutment. DISCUSSION: The design of the implant/implant driver interface effectively prevented the deformation of implant/abutment interface. Little change was noted in the rotational freedom between an implant and its abutment, even though the insertion torque was far beyond clinical application. CONCLUSIONS: The implant/abutment joint of internally connecting implants were quite stable under insertion torque in clinical situation.-
dc.description.statementOfResponsibilityopen-
dc.format.extent37~40-
dc.relation.isPartOfJOURNAL OF ADVANCED PROSTHODONTICS-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.titleThe change of rotational freedom following different insertion torques in three implant systems with implant driver.-
dc.typeArticle-
dc.contributor.collegeCollege of Dentistry (치과대학)-
dc.contributor.departmentDept. of Prosthodontics (보철과학)-
dc.contributor.googleauthorJoo-Hyun Kwon-
dc.contributor.googleauthorChong-Hyun Han-
dc.contributor.googleauthorSun-Jai Kim-
dc.contributor.googleauthorJae-Seung Chang-
dc.identifier.doi10.4047/jap.2009.1.1.37-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA00251-
dc.contributor.localIdA00558-
dc.contributor.localIdA03462-
dc.contributor.localIdA04326-
dc.relation.journalcodeJ01223-
dc.identifier.eissn2005-7814-
dc.identifier.pmid21165253-
dc.subject.keywordmplant driver-
dc.subject.keywordInsertion torque-
dc.subject.keywordInternal connection-
dc.subject.keywordRotational freedom-
dc.contributor.alternativeNameKwon, Joo Hyun-
dc.contributor.alternativeNameKim, Sun Jai-
dc.contributor.alternativeNameChang, Jea Seung-
dc.contributor.alternativeNameHan, Jong Hyoun-
dc.contributor.affiliatedAuthorKwon, Joo Hyun-
dc.contributor.affiliatedAuthorKim, Sun Jai-
dc.contributor.affiliatedAuthorChang, Jea Seung-
dc.contributor.affiliatedAuthorHan, Jong Hyoun-
dc.citation.volume1-
dc.citation.number1-
dc.citation.startPage37-
dc.citation.endPage40-
dc.identifier.bibliographicCitationJOURNAL OF ADVANCED PROSTHODONTICS, Vol.1(1) : 37-40, 2009-
dc.identifier.rimsid56236-
dc.type.rimsART-
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Prosthodontics (보철과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.