2 191

Cited 7 times in

A novel modification of double stapling technique in Billroth I anastomosis

Authors
 JI YEONG AN  ;  SEOK HO YOON  ;  KYUNG HO PAK  ;  GEON-UNG HEO  ;  SUNG JIN OH  ;  WOO JIN HYUNG  ;  SUNG HOON NOH 
Citation
 Journal of Surgical Oncology, Vol.100(6) : 518-519, 2009 
Journal Title
 Journal of Surgical Oncology 
ISSN
 0022-4790 
Issue Date
2009
Abstract
Although the double-stapling technique has been used as a safe procedure in gastroduodenostomy, creating anastomosis with a circular stapler on the linear stapler line can be vulnerable for anastomotic leakage and ischemia. Therefore, we tried to modify the double-stapling technique to avoid stapling on the staple line