Robot-Assisted Radical Prostatectomy in a Patient with a Preexisting Three-Piece Inflatable Penile Prosthesis.
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 이승환 | - |
dc.contributor.author | 정병하 | - |
dc.contributor.author | 최경화 | - |
dc.date.accessioned | 2015-04-23T17:06:34Z | - |
dc.date.available | 2015-04-23T17:06:34Z | - |
dc.date.issued | 2010 | - |
dc.identifier.issn | 2005-6737 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/101837 | - |
dc.description.abstract | We report a rare case of robot-assisted laparoscopic radical prostatectomy (RARP) in a patient with a preexisting penile prosthesis. In this case, we completed RARP without removing the reservoir by using a deflation-inflation technique, and there were no complications related to the prosthesis. The patient had a negative surgical margin. The preserved three-piece inflatable penile prosthesis continued to function properly in 1 month. Reservoir-preserving RARP is technically feasible and safe. However, it is important to be aware of device-related complications. Long-term studies on the mechanical survival rate and patient satisfaction should be also performed | - |
dc.description.statementOfResponsibility | open | - |
dc.format.extent | 70~72 | - |
dc.relation.isPartOf | KOREAN JOURNAL OF UROLOGY | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.title | Robot-Assisted Radical Prostatectomy in a Patient with a Preexisting Three-Piece Inflatable Penile Prosthesis. | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Urology (비뇨기과학) | - |
dc.contributor.googleauthor | Kyung Hwa Choi | - |
dc.contributor.googleauthor | Seung Hwan Lee | - |
dc.contributor.googleauthor | Won Sug Jung | - |
dc.contributor.googleauthor | Byung Ha Chung | - |
dc.identifier.doi | 10.4111/kju.2010.51.1.70 | - |
dc.admin.author | false | - |
dc.admin.mapping | false | - |
dc.contributor.localId | A02938 | - |
dc.contributor.localId | A03607 | - |
dc.contributor.localId | A04036 | - |
dc.relation.journalcode | J02134 | - |
dc.identifier.eissn | 2005-6745 | - |
dc.identifier.pmid | 20414415 | - |
dc.subject.keyword | Penile prosthesis | - |
dc.subject.keyword | Prostatectomy | - |
dc.subject.keyword | Prostatic neoplasms | - |
dc.subject.keyword | Robotics | - |
dc.contributor.alternativeName | Lee, Seung Hwan | - |
dc.contributor.alternativeName | Chung, Byung Ha | - |
dc.contributor.alternativeName | Choi, Kyung Hwa | - |
dc.contributor.affiliatedAuthor | Lee, Seung Hwan | - |
dc.contributor.affiliatedAuthor | Chung, Byung Ha | - |
dc.contributor.affiliatedAuthor | Choi, Kyung Hwa | - |
dc.citation.volume | 51 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 70 | - |
dc.citation.endPage | 72 | - |
dc.identifier.bibliographicCitation | KOREAN JOURNAL OF UROLOGY, Vol.51(1) : 70-72, 2010 | - |