Cited 11 times in
Long-term outcome of single-chamber atrial pacing compared with dual-chamber pacing in patients with sinus-node dysfunction and intact atrioventricular node conduction
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김성순 | - |
dc.contributor.author | 박종성 | - |
dc.contributor.author | 박희남 | - |
dc.contributor.author | 심재민 | - |
dc.contributor.author | 이문형 | - |
dc.contributor.author | 정보영 | - |
dc.contributor.author | 황의석 | - |
dc.date.accessioned | 2015-04-23T17:04:41Z | - |
dc.date.available | 2015-04-23T17:04:41Z | - |
dc.date.issued | 2010 | - |
dc.identifier.issn | 0513-5796 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/101779 | - |
dc.description.abstract | PURPOSE: The optimal pacing mode with either single chamber atrial pacemaker (AAI or AAIR) or dual chamber pacemaker (DDD or DDDR) is still not clear in sinus-node dysfunction (SND) and intact atrioventricular (AV) conduction. MATERIALS AND METHODS: Patients who were implanted with permanent pacemaker using AAI(R) (n = 73) or DDD(R) (n = 113) were compared. RESULTS: The baseline characteristics were comparable between the two groups, with a mean follow-up duration of 69 months. The incidence of death did not show statistical difference. However, the incidence of hospitalization for congestive heart failure (CHF) was significantly lower in the AAI(R) group (0%) than the DDD(R) group (8.8%, p = 0.03). Also, atrial fibrillation (AF) was found in 2.8% in the AAI(R) group, which was statistically different from 15.2% of patients in the DDD(R) group (p = 0.01). Four patients (5.5%) with AAI(R) developed AV block, and subsequently switched to DDD(R) pacing. The risk of AF was lower in the patients implanted with AAI(R) than those with DDD(R) [hazard ratio (HR), 0.84; 95% confidence interval, 0.72 to 0.97, p = 0.02]. CONCLUSION: In patients with SND and intact AV conduction, AAI(R) pacing can achieve a better clinical outcome in terms of occurrence of CHF and AF than DDD(R) pacing. These findings support AAI(R) pacing as the preferred pacing mode in patients with SND and intact AV conduction | - |
dc.description.statementOfResponsibility | open | - |
dc.format.extent | 832~837 | - |
dc.relation.isPartOf | YONSEI MEDICAL JOURNAL | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.subject.MESH | Aged | - |
dc.subject.MESH | Atrial Fibrillation/complications | - |
dc.subject.MESH | Atrial Fibrillation/physiopathology | - |
dc.subject.MESH | Atrioventricular Node/physiopathology* | - |
dc.subject.MESH | Cardiac Pacing, Artificial | - |
dc.subject.MESH | Cohort Studies | - |
dc.subject.MESH | Female | - |
dc.subject.MESH | Follow-Up Studies | - |
dc.subject.MESH | Heart Failure/complications | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Male | - |
dc.subject.MESH | Middle Aged | - |
dc.subject.MESH | Proportional Hazards Models | - |
dc.subject.MESH | Retrospective Studies | - |
dc.subject.MESH | Sick Sinus Syndrome/physiopathology* | - |
dc.subject.MESH | Treatment Outcome | - |
dc.title | Long-term outcome of single-chamber atrial pacing compared with dual-chamber pacing in patients with sinus-node dysfunction and intact atrioventricular node conduction | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Internal Medicine (내과학) | - |
dc.contributor.googleauthor | Won Ho Kim | - |
dc.contributor.googleauthor | Boyoung Joung | - |
dc.contributor.googleauthor | Jaemin Shim | - |
dc.contributor.googleauthor | Jong Sung Park | - |
dc.contributor.googleauthor | Eui-Seock Hwang | - |
dc.contributor.googleauthor | Hui-Nam Pak | - |
dc.contributor.googleauthor | Sungsoon Kim | - |
dc.contributor.googleauthor | Moonhyoung Lee | - |
dc.identifier.doi | 10.3349/ymj.2010.51.6.832 | - |
dc.admin.author | false | - |
dc.admin.mapping | false | - |
dc.contributor.localId | A00573 | - |
dc.contributor.localId | A01659 | - |
dc.contributor.localId | A01776 | - |
dc.contributor.localId | A02206 | - |
dc.contributor.localId | A02766 | - |
dc.contributor.localId | A03609 | - |
dc.contributor.localId | A04480 | - |
dc.relation.journalcode | J02813 | - |
dc.identifier.eissn | 1976-2437 | - |
dc.identifier.pmid | 20879047 | - |
dc.subject.keyword | Sinus node dysfunction | - |
dc.subject.keyword | intact AV conduction | - |
dc.contributor.alternativeName | Kim, Sung Soon | - |
dc.contributor.alternativeName | Park, Jong Seoung | - |
dc.contributor.alternativeName | Pak, Hui Nam | - |
dc.contributor.alternativeName | Shim, Jae Min | - |
dc.contributor.alternativeName | Lee, Moon Hyoung | - |
dc.contributor.alternativeName | Joung, Bo Young | - |
dc.contributor.alternativeName | Hwang, Eui Seock | - |
dc.contributor.affiliatedAuthor | Kim, Sung Soon | - |
dc.contributor.affiliatedAuthor | Park, Jong Seoung | - |
dc.contributor.affiliatedAuthor | Pak, Hui Nam | - |
dc.contributor.affiliatedAuthor | Shim, Jae Min | - |
dc.contributor.affiliatedAuthor | Lee, Moon Hyoung | - |
dc.contributor.affiliatedAuthor | Joung, Bo Young | - |
dc.contributor.affiliatedAuthor | Hwang, Eui Seock | - |
dc.citation.volume | 51 | - |
dc.citation.number | 6 | - |
dc.citation.startPage | 832 | - |
dc.citation.endPage | 837 | - |
dc.identifier.bibliographicCitation | YONSEI MEDICAL JOURNAL, Vol.51(6) : 832-837, 2010 | - |
dc.identifier.rimsid | 54600 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.