206 524

Cited 10 times in

Comparisons of the effects of stent eccentricity on the neointimal hyperplasia between sirolimus-eluting stent versus paclitaxel-eluting stent

DC Field Value Language
dc.contributor.author홍명기-
dc.contributor.author고영국-
dc.contributor.author김병극-
dc.contributor.author김중선-
dc.contributor.author장양수-
dc.contributor.author최동훈-
dc.date.accessioned2015-04-23T17:04:37Z-
dc.date.available2015-04-23T17:04:37Z-
dc.date.issued2010-
dc.identifier.issn0513-5796-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/101777-
dc.description.abstractPURPOSE: Previous studies suggested that asymmetric stent expansion did not affect suppression of neointimal hyperplasia (NIH) after sirolimus-eluting stents (SES) implantation. The aim of this study was to evaluate the effects of stent eccentricity (SE) on NIH between SES versus paclitaxel-eluting stents (PES) using an intravascular ultrasound (IVUS) analysis from the randomized trial. MATERIALS AND METHODS: Serial IVUS data were obtained from Post-stent Optimal Expansion (POET) trial, allocated randomly to SES or PES. Three different SE (minimum stent diameter divided by maximum stent diameter) were evaluated; SE at the lesion site with maximal %NIH area (SE-NIH), SE at the minimal stent CSA [SE-minimal stent area (SE-MSA)], and averaged SE through the entire stent (SE-mean). We classified each drug-eluting stents (DES) into the concentric (≥ mean SE) and eccentric groups (< mean SE) based on the mean value of SE. RESULTS: Among 301 enrolled patients, 233 patients [SES (n = 108), PES (n = 125)] underwent a follow-up IVUS. There was no significant correlation between %NIH area and SE-NIH (r = - 0.083, p = 0.391) or SE-MSA (r = - 0.109, p = 0.259) of SES. However, SE-NIH of PES showed a weak but significant correlation with %NIH area (r = 0.269, p < 0.01). As to the associations between SEmean and NIH volume index, SES revealed no significant correlation (r = - 0.001, p = 0.990), but PES showed a weak but significant correlation (r = 0.320, p < 0.01). However, there was no difference in the restenosis rate between the eccentric versus concentric groups of both DES. CONCLUSION: This study suggests that lower SE of both SES and PES, which means asymmetric stent expansion, may not be associated with increased NIH.-
dc.description.statementOfResponsibilityopen-
dc.format.extent823~831-
dc.relation.isPartOfYONSEI MEDICAL JOURNAL-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAged-
dc.subject.MESHAngiography/methods-
dc.subject.MESHCoronary Restenosis/diagnostic imaging-
dc.subject.MESHCoronary Restenosis/pathology-
dc.subject.MESHDrug-Eluting Stents*-
dc.subject.MESHFemale-
dc.subject.MESHHumans-
dc.subject.MESHHyperplasia/drug therapy*-
dc.subject.MESHHyperplasia/pathology-
dc.subject.MESHImmunosuppressive Agents/administration & dosage-
dc.subject.MESHMale-
dc.subject.MESHMiddle Aged-
dc.subject.MESHPaclitaxel/administration & dosage*-
dc.subject.MESHSirolimus/administration & dosage*-
dc.subject.MESHTunica Intima-
dc.subject.MESHUltrasonography, Interventional/methods-
dc.titleComparisons of the effects of stent eccentricity on the neointimal hyperplasia between sirolimus-eluting stent versus paclitaxel-eluting stent-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Internal Medicine (내과학)-
dc.contributor.googleauthorByeong-Keuk Kim-
dc.contributor.googleauthorYoung-Guk Ko-
dc.contributor.googleauthorSeungjin Oh-
dc.contributor.googleauthorJung-Sun Kim-
dc.contributor.googleauthorWoong Chol Kang-
dc.contributor.googleauthorDong Woon Jeon-
dc.contributor.googleauthorJoo Young Yang-
dc.contributor.googleauthorDonghoon Choi-
dc.contributor.googleauthorMyeong-Ki Hong-
dc.contributor.googleauthorTaehoon Ahn-
dc.contributor.googleauthorYangsoo Jang-
dc.identifier.doi10.3349/ymj.2010.51.6.823-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA04391-
dc.contributor.localIdA00127-
dc.contributor.localIdA00493-
dc.contributor.localIdA00961-
dc.contributor.localIdA03448-
dc.contributor.localIdA04053-
dc.relation.journalcodeJ02813-
dc.identifier.eissn1976-2437-
dc.identifier.pmid20879046-
dc.subject.keywordDrug-eluting stents-
dc.subject.keywordintravascular ultrasonography-
dc.subject.keywordrestenosis-
dc.contributor.alternativeNameHong, Myeong Ki-
dc.contributor.alternativeNameKo, Young Guk-
dc.contributor.alternativeNameKim, Byeong Keuk-
dc.contributor.alternativeNameKim, Jung Sun-
dc.contributor.alternativeNameJang, Yang Soo-
dc.contributor.alternativeNameChoi, Dong Hoon-
dc.contributor.affiliatedAuthorHong, Myeong Ki-
dc.contributor.affiliatedAuthorKo, Young Guk-
dc.contributor.affiliatedAuthorKim, Byeong Keuk-
dc.contributor.affiliatedAuthorKim, Jung Sun-
dc.contributor.affiliatedAuthorJang, Yang Soo-
dc.contributor.affiliatedAuthorChoi, Dong Hoon-
dc.citation.volume51-
dc.citation.number6-
dc.citation.startPage823-
dc.citation.endPage831-
dc.identifier.bibliographicCitationYONSEI MEDICAL JOURNAL, Vol.51(6) : 823-831, 2010-
dc.identifier.rimsid54598-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.