692 620

Cited 0 times in

초음파 기기를 이용한 촉지되지 않는 임플라논의 제거

DC Field Value Language
dc.contributor.author서경-
dc.date.accessioned2015-04-23T17:03:48Z-
dc.date.available2015-04-23T17:03:48Z-
dc.date.issued2010-
dc.identifier.issn1738-5628-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/101752-
dc.description.abstractOBJECTIVE: This study was designed to analyze outcome of removal of non-palpable Implanon(TM) by ultrasound guidance. METHODS: This is retrospective study of patients who were referred from local clinic where removal of non-palpable Implanon(TM) had been failed. The cases were 32 patients who visited to Yonsei University Gangnam Severance Hospital between March 2004 through March 2009. RESULTS: Implanons(TM) were localized on ultrasound in all 32 cases. 18 cases were located in subcutaneous layer, 10 cased were located in fascial layer, 4 cases were located in muscle layer. All cases were successfully removed. The average length of time required for removal was 19.3 minutes. There was no complication except one patient, who had mild median nerve injury. CONCLUSION: Ultrasound guidance removal was safe and effective procedure to remove non palpable Implanon(TM).-
dc.description.statementOfResponsibilityopen-
dc.format.extent506~511-
dc.relation.isPartOfKorean Journal of Obstetrics and Gynecology (대한산부인과학회지)-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.title초음파 기기를 이용한 촉지되지 않는 임플라논의 제거-
dc.title.alternativeRemoval of non-palpable Implanon(TM) by ultrasound guidance-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Obstetrics & Gynecology (산부인과학)-
dc.contributor.googleauthor김선영-
dc.contributor.googleauthor허지수-
dc.contributor.googleauthor장민영-
dc.contributor.googleauthor홍 연-
dc.contributor.googleauthor최보람-
dc.contributor.googleauthor백정혜-
dc.contributor.googleauthor서 경-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA01869-
dc.relation.journalcodeJ02076-
dc.subject.keywordRemoval of non-palpable ImplanonTM-
dc.subject.keywordUltrasound guidance-
dc.contributor.alternativeNameSeo, Kyung-
dc.contributor.affiliatedAuthorSeo, Kyung-
dc.citation.volume53-
dc.citation.number6-
dc.citation.startPage506-
dc.citation.endPage511-
dc.identifier.bibliographicCitationKorean Journal of Obstetrics and Gynecology (대한산부인과학회지), Vol.53(6) : 506-511, 2010-
dc.identifier.rimsid46711-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Obstetrics and Gynecology (산부인과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.