439 651

Cited 39 times in

A Pilot Study of Sequential Capsule Endoscopy Using MiroCam and PillCam SB Devices with Different Transmission Technologies

DC Field Value Language
dc.contributor.author박승우-
dc.contributor.author박정엽-
dc.contributor.author방승민-
dc.contributor.author송시영-
dc.contributor.author신성관-
dc.contributor.author이상길-
dc.contributor.author이용찬-
dc.contributor.author천재희-
dc.date.accessioned2015-04-23T16:46:46Z-
dc.date.available2015-04-23T16:46:46Z-
dc.date.issued2010-
dc.identifier.issn1976-2283-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/101209-
dc.description.abstractBACKGROUND/AIMS: Studies have investigated the use of different types of radiofrequency capsules for comparison or sequential capsule endoscopy, but none have compared the MiroCam device - which utilizes a novel data transmission technology - with other capsules. This study compared the feasibility of sequential capsule endoscopy using the MiroCam and PillCam SB devices, which employ different transmission technologies. METHODS: Patients with diseases requiring capsule endoscopy were enrolled. After a 12-hour fast, one randomly selected capsule was swallowed. The second capsule was swallowed once fluoroscopy had indicated that the first capsule had migrated below the gastric outlet. RESULTS: The total operating time in 24 patients was 702+/-60 min (mean+/-SD) for the MiroCam and 446+/-28 min for the PillCam SB (p<0.0001). The rate of a complete examination to the cecum was 83.3% for the MiroCam and 58.3% for the PillCam SB (p=0.031). Diagnostic yields for the MiroCam, PillCam SB, and sequential capsule endoscopy were 45.8%, 41.7%, and 50.0%, respectively. The agreement rate between the two capsules was 87.5%, with a kappa value of 0.74. Electrical interference in data transmission between the two capsules was not observed, but temporary visual interferences were observed in seven patients (29.2%). CONCLUSIONS: Sequential capsule endoscopy with the MiroCam and PillCam SB produced slight but nonsignificant increases in the diagnostic yield, and the two capsules did not exhibit electrical interference. A larger trial is necessary for elucidating the usefulness of sequential capsule endoscopy.-
dc.description.statementOfResponsibilityopen-
dc.format.extent192~200-
dc.relation.isPartOfGUT AND LIVER-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.titleA Pilot Study of Sequential Capsule Endoscopy Using MiroCam and PillCam SB Devices with Different Transmission Technologies-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Internal Medicine (내과학)-
dc.contributor.googleauthorHee Man Kim-
dc.contributor.googleauthorYoon Jae Kim-
dc.contributor.googleauthorHong Jeong Kim-
dc.contributor.googleauthorSemi Park-
dc.contributor.googleauthorJeong Youp Park-
dc.contributor.googleauthorSung Kwan Shin-
dc.contributor.googleauthorJae Hee Cheon-
dc.contributor.googleauthorSang Kil Lee-
dc.contributor.googleauthorYong Chan Lee-
dc.contributor.googleauthorSeung Woo Park-
dc.contributor.googleauthorSeungmin Bang-
dc.contributor.googleauthorSi Young Song-
dc.identifier.doi10.5009/gnl.2010.4.2.192-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA01551-
dc.contributor.localIdA01647-
dc.contributor.localIdA01786-
dc.contributor.localIdA02035-
dc.contributor.localIdA02112-
dc.contributor.localIdA02812-
dc.contributor.localIdA02988-
dc.contributor.localIdA04030-
dc.relation.journalcodeJ00954-
dc.identifier.eissn2005-1212-
dc.identifier.pmid20559521-
dc.subject.keywordCapsule endoscopy-
dc.subject.keywordDiagnosis-
dc.subject.keywordFeasibility study-
dc.subject.keywordGastrointestinal hemorrhage-
dc.contributor.alternativeNamePark, Seung Woo-
dc.contributor.alternativeNamePark, Jeong Youp-
dc.contributor.alternativeNameBang, Seung Min-
dc.contributor.alternativeNameSong, Si Young-
dc.contributor.alternativeNameShin, Sung Kwan-
dc.contributor.alternativeNameLee, Sang Kil-
dc.contributor.alternativeNameLee, Yong Chan-
dc.contributor.alternativeNameCheon, Jae Hee-
dc.contributor.affiliatedAuthorPark, Seung Woo-
dc.contributor.affiliatedAuthorPark, Jeong Youp-
dc.contributor.affiliatedAuthorBang, Seung Min-
dc.contributor.affiliatedAuthorSong, Si Young-
dc.contributor.affiliatedAuthorShin, Sung Kwan-
dc.contributor.affiliatedAuthorLee, Sang Kil-
dc.contributor.affiliatedAuthorLee, Yong Chan-
dc.contributor.affiliatedAuthorCheon, Jae Hee-
dc.citation.volume4-
dc.citation.number2-
dc.citation.startPage192-
dc.citation.endPage200-
dc.identifier.bibliographicCitationGUT AND LIVER, Vol.4(2) : 192-200, 2010-
dc.identifier.rimsid52133-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.