0 685

Cited 17 times in

Modified Siepser sliding knot technique for scleral fixation of subluxated posterior chamber intraocular lens

Authors
 Kyoung Tak Ma  ;  Sung Yong Kang  ;  Joo Youn Shin  ;  Na Rae Kim  ;  Gong Je Seong  ;  Chan Yun Kim 
Citation
 JOURNAL OF CATARACT AND REFRACTIVE SURGERY, Vol.36(1) : 6-8, 2010 
Journal Title
JOURNAL OF CATARACT AND REFRACTIVE SURGERY
ISSN
 0886-3350 
Issue Date
2010
MeSH
Child ; Humans ; IntraocularPressure ; LensImplantation,Intraocular/methods* ; Lenses,Intraocular* ; Male ; Middle Aged ; Prosthesis Failure* ; Refraction, Ocular/physiology ; Sclera/surgery* ; Suture Techniques* ; Visual Acuity/physiology
Abstract
We describe a new technique of scleral fixation for the management of dislocated intraocular lenses (IOL). A suture is tied inside the eye around the dislocated haptic to prevent slippage of the IOL after surgery. The technique, which is safe and less invasive than previous methods, was used in 3 patients and the results are presented.

FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned
Full Text
http://www.sciencedirect.com/science/article/pii/S0886335009009882
DOI
10.1016/j.jcrs.2009.07.048
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Ophthalmology (안과학교실) > 1. Journal Papers
Yonsei Authors
Kim, Na Rae(김나래)
Kim, Chan Yun(김찬윤) ORCID logo https://orcid.org/0000-0002-8373-9999
Seong, Gong Je(성공제) ORCID logo https://orcid.org/0000-0002-5456-4296
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/100435
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.