Evaluation of performance including influence by interfering substances of the Innovance D-dimer assay on the Sysmex coagulation analyzer.

DC Field Value Language
dc.contributor.author박서진-
dc.date.accessioned2014-12-20T17:44:23Z-
dc.date.available2014-12-20T17:44:23Z-
dc.date.issued2011-
dc.identifier.issn0091-7370-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/95171-
dc.description.abstractD-dimer is formed during activation of the coagulation system and is commonly assayed in order to diagnose disseminated intravascular coagulation, deep vein thrombosis, and pulmonary embolism. Enzyme-linked immunosorbent assay has been validated as the reference method, but it is a time-consuming procedure. The objective of this study was to evaluate a new immunoturbidimetric, particle-enhanced, Innovance(®) D-dimer immunoassay. A total of 129 plasma samples from apparently healthy individuals and 298 samples from patients were collected for linearity, precision, and correlation studies. Testing the precision of low- and high-controls yielded CV values of 2.08% and 1.76%, respectively. The central 95% non-parametric reference interval estimated from healthy controls was 0.093-0.68 mg/L Fibrinogen Equivalent Units (FEU; median, 0.26 mg/L FEU). Comparison analysis yielded acceptable correlation with the STA Liatest(®) D-dimer assay (R(2) = 0.9471). At a cut-off level of <0.5 mg/L FEU, the sensitivity and specificity indices of the Innovance D-dimer assay were 99.7% and 89.1%, respectively. Thus the Innovance D-dimer method showed acceptable precision and linearity, and the assay results showed acceptable correlation with the STA Liatest D-dimer method. The Innovance method was relatively unaffected by potential interfering substances such as bilirubin and hemoglobin. In conclusion, the Innovance D-dimer assay is suitable for monitoring D-dimer concentrations in various clinical conditions and should be useful in clinical laboratories.-
dc.description.statementOfResponsibilityopen-
dc.format.extent20~24-
dc.relation.isPartOfANNALS OF CLINICAL AND LABORATORY SCIENCE-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAdolescent-
dc.subject.MESHAdult-
dc.subject.MESHAged-
dc.subject.MESHAged, 80 and over-
dc.subject.MESHBilirubin/metabolism*-
dc.subject.MESHBlood Coagulation Tests/instrumentation*-
dc.subject.MESHBlotting, Western-
dc.subject.MESHChild-
dc.subject.MESHChild, Preschool-
dc.subject.MESHFemale-
dc.subject.MESHFibrin Fibrinogen Degradation Products/analysis*-
dc.subject.MESHHemoglobins/metabolism*-
dc.subject.MESHHumans-
dc.subject.MESHImmunoassay/methods*-
dc.subject.MESHInfant-
dc.subject.MESHInfant, Newborn-
dc.subject.MESHMale-
dc.subject.MESHMiddle Aged-
dc.subject.MESHYoung Adult-
dc.titleEvaluation of performance including influence by interfering substances of the Innovance D-dimer assay on the Sysmex coagulation analyzer.-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Laboratory Medicine (진단검사의학)-
dc.contributor.googleauthorSeo-Jin Park-
dc.contributor.googleauthorHyun-Sook Chi-
dc.contributor.googleauthorSoh Hyun Chun-
dc.contributor.googleauthorSeongsoo Jang-
dc.contributor.googleauthorChan-Jeoung Park-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA01494-
dc.relation.journalcodeJ00155-
dc.identifier.eissn1550-8080-
dc.identifier.pmid21325250-
dc.identifier.urlhttp://www.annclinlabsci.org/content/41/1/20.long-
dc.contributor.alternativeNamePark, Seo Jin-
dc.contributor.affiliatedAuthorPark, Seo Jin-
dc.rights.accessRightsnot free-
dc.citation.volume41-
dc.citation.number1-
dc.citation.startPage20-
dc.citation.endPage24-
dc.identifier.bibliographicCitationANNALS OF CLINICAL AND LABORATORY SCIENCE, Vol.41(1) : 20-24, 2011-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Laboratory Medicine (진단검사의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.