Cited 0 times in

46 11

연마시스템에 따른 복합레진의 표면거칠기와 연마시간에 대한 평가

Other Titles
 The evaluation of surface roughness and polishing time between polishing systems 
Authors
 박정원 ; 송민주 ; 신수정 
Citation
 Journal of Korean Academy of Conservative Dentistry(대한치과보존학회지), Vol.36(2) : 119~124, 2011 
Journal Title
 Journal of Korean Academy of Conservative Dentistry(대한치과보존학회지) 
ISSN
 1225-0864 
Issue Date
2011
Abstract
Objectives: The purpose of this experiment was to evaluate four different polishing systems of their polishability and polishing time. Materials and Methods: 4 mm diameter and 2 mm thickness Teflon mold was made. Z-250 (3M ESPE) hybrid composite resin was slightly overfilled and pressed with slide glass and cured with Optilux 501 for 40 sec each side. Then the surface roughness (glass pressed: control group) was measured with profilometer. One surface of the specimen was roughened by #320 grit sand paper and polished with one of the following polishing systems; Sof-Lex (3M ESPE), Jiffy (Ultradent), Enhance (Dentsply/Caulk), or Pogo (Dentsply/Caulk). The surface roughness and the total polishing time were measured. The results were analyzed with one-way ANOVA and Duncan’s multiple range test. Results: The surface roughness was lowest in Pogo, and highest in Sof-Lex. Polishing times were shortest with Pogo, and followed by the Sof-Lex, Enhance and Jiffy. Conclusions: One-step polishing system (Pogo) is very effective to get the smooth surface in a short time, therefore it can be recommended for final polishing system of the restoration.
URI
http://ir.ymlib.yonsei.ac.kr/handle/22282913/95053
DOI
10.5395/JKACD.2011.36.2.119
Appears in Collections:
1. 연구논문 > 2. College of Dentistry > Dept. of Conservative Dentistry
Yonsei Authors
사서에게 알리기
  feedback
Files in This Item:
T201105253.pdfDownload
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse