369 569

Cited 10 times in

Comparison of patient outcomes after implantation of Visian toric implantable collamer lens and iris-fixated toric phakic intraocular lens.

DC Field Value Language
dc.contributor.author김응권-
dc.contributor.author김태임-
dc.contributor.author서경률-
dc.contributor.author이상엽-
dc.date.accessioned2014-12-20T17:36:09Z-
dc.date.available2014-12-20T17:36:09Z-
dc.date.issued2011-
dc.identifier.issn0950-222X-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/94912-
dc.description.abstractPURPOSE: We compared visual and refractive outcomes after implantation of Visian toric implantable collamer lenses (toric ICLs) and iris-fixated toric pIOLs (toric Artisans). PATIENTS AND METHODS: A comparative retrospective analysis was performed. Toric ICLs were implanted into 30 eyes of 18 patients, and toric Artisans into 31 eyes of 22 recipients. We measured the logarithms of the minimum angle of resolution of uncorrected visual acuity (logMAR UCVA), logMAR of best spectacle-corrected corrected VA (logMAR BSCVA), MR, SE, and astigmatism (by the power vector method) before surgery and 1, 3, and 6 months thereafter. Differences between patients receiving each type of lens were compared by using a mixed model of repeated measures. RESULTS: Visual improvements were evident after operation in both groups. By comparing the attempted to the achieved SE values, we were able to confirm that correction of refractive error was similar in both groups. However, the logMAR UCVA was significantly higher in the toric ICL group at all postoperative time points. Although manifest cylinder power and astigmatism (calculated by using the power vector method) gradually decreased in the toric ICL group, cylinder power 1 month postoperatively increased from -2.62 to -2.75 D; astigmatism was also increased at this time in the toric Artisan group. CONCLUSION: The two tested toric pIOLs were similar in terms of the ability to correct refractive error, as assessed 3 months postoperatively. However toric ICLs corrected astigmatism more rapidly and safely. Notably, the large difference in astigmatism level between the two groups 1 month postoperatively indicates that toric ICLs are more effective when used to correct astigmatism.-
dc.description.statementOfResponsibilityopen-
dc.formatapplication/pdf-
dc.relation.isPartOfEYE-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAdult-
dc.subject.MESHAlgorithms-
dc.subject.MESHAstigmatism/physiopathology-
dc.subject.MESHAstigmatism/surgery*-
dc.subject.MESHFemale-
dc.subject.MESHHumans-
dc.subject.MESHLens Implantation, Intraocular/methods*-
dc.subject.MESHLenses, Intraocular*-
dc.subject.MESHMale-
dc.subject.MESHMiddle Aged-
dc.subject.MESHMyopia/physiopathology-
dc.subject.MESHMyopia/surgery*-
dc.subject.MESHRefraction, Ocular/physiology-
dc.subject.MESHRetrospective Studies-
dc.subject.MESHVisual Acuity/physiology*-
dc.subject.MESHYoung Adult-
dc.titleComparison of patient outcomes after implantation of Visian toric implantable collamer lens and iris-fixated toric phakic intraocular lens.-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Ophthalmology (안과학)-
dc.contributor.googleauthorSY Lee-
dc.contributor.googleauthorHJ Kwon-
dc.contributor.googleauthorHS Ahn-
dc.contributor.googleauthorKY Seo-
dc.contributor.googleauthorEK Kim-
dc.contributor.googleauthorT-I Kim-
dc.identifier.doi10.1038/eye.2011.176-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA00831-
dc.contributor.localIdA01080-
dc.contributor.localIdA01870-
dc.relation.journalcodeJ00886-
dc.identifier.eissn1476-5454-
dc.identifier.pmid21852802-
dc.subject.keywordVisian toric implantable collamer lens-
dc.subject.keywordiris-fixated toric phakic intraocular lens-
dc.subject.keywordVerisys intraocular lens-
dc.subject.keywordphakic intraocular lens-
dc.subject.keywordcorrection of astigmatism-
dc.contributor.alternativeNameKim, Eung Kweon-
dc.contributor.alternativeNameKim, Tae Im-
dc.contributor.alternativeNameSeo, Kyuong Yul-
dc.contributor.affiliatedAuthorKim, Eung Kweon-
dc.contributor.affiliatedAuthorKim, Tae Im-
dc.contributor.affiliatedAuthorSeo, Kyuong Yul-
dc.rights.accessRightsfree-
dc.citation.volume25-
dc.citation.number11-
dc.citation.startPage1409-
dc.citation.endPage1417-
dc.identifier.bibliographicCitationEYE, Vol.25(11) : 1409-1417, 2011-
dc.identifier.rimsid27847-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Ophthalmology (안과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.