396 446

Cited 0 times in

Accurate Localization of Metal Electrodes Using Magnetic Resonance Imaging

Other Titles
 자기공명영상을 이용한 금속전극의 정확한 위치 결정 
Authors
 Eunhae Joe  ;  Min-Oh Ghim  ;  Yoon Ha  ;  Dong-Hyun Kim 
Citation
 Journal of the Korean Society of Magnetic Resonance in Medicine (대한자기공명의과학회지), Vol.15(1) : 11-21, 2011 
Journal Title
Journal of the Korean Society of Magnetic Resonance in Medicine(대한자기공명의과학회지)
ISSN
 1226-9751 
Issue Date
2011
Keywords
Microelectrode localization ; Field inhomogeneity ; Susceptibility artifact ; Metallic artifact
Abstract
PURPOSE: Localization using MRI is difficult due to susceptibility induced artifacts caused by metal electrodes. Here we took an advantage of the B0 pattern induced by the metal electrodes by using an oblique-view imaging method. MATERIALS AND METHODS: Metal electrode models with various diameters and susceptibilities were simulated to understand the aspect of field distortion. We set localization criteria for a turbo spin-echo (TSE) sequence usingconventional (90degrees view) and 45degrees oblique-view imaging method through simulation of images with various resolutions and validated the criteria usingphantom images acquired by a 3.0T clinical MRI system. For a gradient-refocused echo (GRE) sequence, which is relatively more sensitive to field inhomogeneity, we used phase images to find the center of electrode. RESULTS: There was least field inhomogeneity along the 45degrees line that penetrated the center of the electrode. Therefore, our criteria for the TSE sequence with 45degrees oblique-view was coincided regardless of susceptibility. And with 45degrees oblique-view angle images, pixel shifts were bidirectional so we can detect the location of electrodes even in low resolution. For the GRE sequence, the 45degrees oblique-view anglemethod madethe lines where field polarity changes become coincident to the Cartesian grid so the localization of the center coordinates was more facilitated. CONCLUSION: We suggested the method for accurate localization of electrode using 45degrees oblique-view angle imaging. It is expected to be a novelmethodto monitoring an electrophysiological brain study and brain neurosurgery
Files in This Item:
T201101596.pdf Download
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Neurosurgery (신경외과학교실) > 1. Journal Papers
Yonsei Authors
Ha, Yoon(하윤)
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/93358
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links