3 789

Cited 24 times in

Comparison of outcomes among secondary covered metallic, uncovered metallic, and plastic biliary stents in treating occluded primary metallic stents in malignant distal biliary obstruction

DC Field Value Language
dc.contributor.author김윤재-
dc.contributor.author김희만-
dc.contributor.author박승우-
dc.contributor.author박정엽-
dc.contributor.author방승민-
dc.contributor.author송시영-
dc.contributor.author전태주-
dc.contributor.author정재복-
dc.contributor.author조재희-
dc.date.accessioned2014-12-20T16:26:35Z-
dc.date.available2014-12-20T16:26:35Z-
dc.date.issued2011-
dc.identifier.issn0930-2794-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/92725-
dc.description.abstractBACKGROUND: The self-expandable metallic stent (SEMS) has been widely used for unresectable malignant biliary obstruction but eventually becomes occluded by tumor ingrowth/overgrowth and sludge. Therefore, we aimed to determine the therapeutic effectiveness of secondary stents and to find differences according to various combinations of the first and second stents for the management of occluded SEMSs in patients with malignant distal biliary obstruction. METHODS: Between 1999 and November 2008, 77 patients with malignant biliary obstruction underwent secondary biliary stent placement as "stent-in-stent" at three university hospitals in Korea (40 covered, 26 uncovered, and 11 plastic stents). The membrane of the covered SEMS was regarded as the barrier against tumor ingrowth. We categorized the patients into three groups based on whether the covered SEMS was either the first or the second stent: membrane-SEMS (18 covered-covered; 9 covered-uncovered; 22 uncovered-covered SEMS), bare-SEMS (17 uncovered-uncovered SEMS), and plastic stent (3 covered-plastic; 8 uncovered-plastic). RESULTS: The median patency of second stents was 138, 109, and 88 days (covered, uncovered, and plastic stents). The second covered SEMSs had a significantly longer patency than plastic stents (p=0.047). In a multivariate analysis including membrane-SEMS, bare-SEMS, and plastic stent groups, the bare-SEMS had a worse cumulative stent patency (HR=2.04, CI=1.08-3.86) and survival time (HR=2.37, CI=1.25-4.49) than the membrane-SEMS. Patients with ampulla of Vater cancer had better stent patency (HR=0.27, CI=0.08-0.98) and survival (HR=0.17, CI=0.04-0.77) than those with other pancreatobiliary malignancies. In addition, antitumor treatment prolonged survival time (HR=0.50, CI=0.26-0.99). CONCLUSIONS: The placement of additional biliary stents using the "stent-in-stent" method is an effective treatment for an occluded metallic primary stent. In addition, double biliary SEMS placement using at least one covered SEMS (in the primary and/or secondary procedure) might provide longer cumulative stent patency and survival than using uncovered SEMSs in both procedures.-
dc.description.statementOfResponsibilityopen-
dc.format.extent475~482-
dc.relation.isPartOfSURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAged-
dc.subject.MESHAged, 80 and over-
dc.subject.MESHBiliary Tract Neoplasms/complications-
dc.subject.MESHBiliary Tract Neoplasms/pathology*-
dc.subject.MESHCholestasis, Intrahepatic/mortality-
dc.subject.MESHCholestasis, Intrahepatic/pathology*-
dc.subject.MESHCholestasis, Intrahepatic/surgery*-
dc.subject.MESHCoated Materials, Biocompatible-
dc.subject.MESHCohort Studies-
dc.subject.MESHFemale-
dc.subject.MESHFollow-Up Studies-
dc.subject.MESHHumans-
dc.subject.MESHKaplan-Meier Estimate-
dc.subject.MESHMetals-
dc.subject.MESHMiddle Aged-
dc.subject.MESHNeoplasm Staging-
dc.subject.MESHPalliative Care/methods-
dc.subject.MESHPlastics-
dc.subject.MESHProportional Hazards Models-
dc.subject.MESHProsthesis Design-
dc.subject.MESHProsthesis Failure-
dc.subject.MESHProsthesis Implantation/methods*-
dc.subject.MESHReoperation-
dc.subject.MESHRetrospective Studies-
dc.subject.MESHRisk Assessment-
dc.subject.MESHStents*-
dc.subject.MESHSurvival Analysis-
dc.subject.MESHTime Factors-
dc.subject.MESHTreatment Outcome-
dc.titleComparison of outcomes among secondary covered metallic, uncovered metallic, and plastic biliary stents in treating occluded primary metallic stents in malignant distal biliary obstruction-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Internal Medicine (내과학)-
dc.contributor.googleauthorJae Hee Cho-
dc.contributor.googleauthorTae Joo Jeon-
dc.contributor.googleauthorJeong Youp Park-
dc.contributor.googleauthorHee Man Kim-
dc.contributor.googleauthorYoon Jae Kim-
dc.contributor.googleauthorSeung Woo Park-
dc.contributor.googleauthorJae Bock Chung-
dc.contributor.googleauthorSi Young Song-
dc.contributor.googleauthorSeungmin Bang-
dc.identifier.doi10.1007/s00464-010-1196-6-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA00792-
dc.contributor.localIdA01210-
dc.contributor.localIdA01551-
dc.contributor.localIdA01647-
dc.contributor.localIdA01786-
dc.contributor.localIdA02035-
dc.contributor.localIdA03706-
dc.contributor.localIdA03902-
dc.contributor.localIdA03557-
dc.relation.journalcodeJ02703-
dc.identifier.eissn1432-2218-
dc.identifier.pmid20602138-
dc.identifier.urlhttp://link.springer.com/article/10.1007%2Fs00464-010-1196-6-
dc.subject.keywordMalignant biliary obstruction-
dc.subject.keywordSelf-expandable metallic stent-
dc.subject.keywordPlastic stent-
dc.subject.keywordOcclusion-
dc.subject.keywordStent patency-
dc.subject.keywordSurvival-
dc.contributor.alternativeNameKim, Yoon Jae-
dc.contributor.alternativeNameKim, Hee Man-
dc.contributor.alternativeNamePark, Seung Woo-
dc.contributor.alternativeNamePark, Jeong Youp-
dc.contributor.alternativeNameBang, Seung Min-
dc.contributor.alternativeNameSong, Si Young-
dc.contributor.alternativeNameJeon, Tae Joo-
dc.contributor.alternativeNameChung, Jae Bock-
dc.contributor.alternativeNameCho, Jae Hee-
dc.contributor.affiliatedAuthorKim, Yoon Jae-
dc.contributor.affiliatedAuthorKim, Hee Man-
dc.contributor.affiliatedAuthorPark, Seung Woo-
dc.contributor.affiliatedAuthorPark, Jeong Youp-
dc.contributor.affiliatedAuthorBang, Seung Min-
dc.contributor.affiliatedAuthorSong, Si Young-
dc.contributor.affiliatedAuthorChung, Jae Bock-
dc.contributor.affiliatedAuthorCho, Jae Hee-
dc.contributor.affiliatedAuthorJeon, Tae Joo-
dc.rights.accessRightsnot free-
dc.citation.volume25-
dc.citation.number2-
dc.citation.startPage475-
dc.citation.endPage482-
dc.identifier.bibliographicCitationSURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, Vol.25(2) : 475-482, 2011-
dc.identifier.rimsid28720-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.