4 482

Cited 0 times in

Optical coherence tomographic comparison of neointimal coverage between sirolimus- and resolute zotarolimus-eluting stents at 9 months after stent implantation.

Authors
 Jung-Sun Kim  ;  Jin-Sun Kim  ;  Dong-Ho Shin  ;  Byeong-Keuk Kim  ;  Young-Guk Ko  ;  Donghoon Choi  ;  Yangsoo Jang  ;  Myeong-Ki Hong 
Citation
 INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, Vol.28(6) : 1281-1287, 2012 
Journal Title
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING
ISSN
 1569-5794 
Issue Date
2012
MeSH
Aged ; Cardiovascular Agents/administration & dosage* ; Chi-Square Distribution ; Coronary Angiography ; Coronary Artery Disease/diagnostic imaging ; Coronary Artery Disease/therapy* ; Coronary Thrombosis/etiology ; Coronary Thrombosis/pathology ; Coronary Thrombosis/prevention & control ; Coronary Vessels/pathology* ; Drug-Eluting Stents* ; Female ; Humans ; Linear Models ; Male ; Middle Aged ; Multivariate Analysis ; Neointima* ; Percutaneous Coronary Intervention/adverse effects ; Percutaneous Coronary Intervention/instrumentation* ; Predictive Value of Tests ; Prosthesis Design ; Registries ; Retrospective Studies ; Sirolimus/administration & dosage ; Sirolimus/analogs & derivatives* ; Time Factors ; Tomography, Optical Coherence* ; Treatment Outcome
Keywords
Optical coherence tomography ; Stent
Abstract
The Resolute zotarolimus-eluting stent (ZES-R) has a thinner stent strut with biocompatible polymer than first generation drug-eluting stents. However, minimal optical coherence tomography (OCT) data exists about vascular responses after ZES-R implantation. This study investigated OCT findings in ZES-R implantation and compared them to those in sirolimus-eluting stent (SES) implantation. A total of 123 lesions (43 ZES-R and 80 SES) in 111 patients were evaluated with OCT at 9 months after stent implantation. Strut apposition, neointimal hyperplasia (NIH) thickness, and stent coverage on each stent strut were evaluated. Mean NIH thickness was significantly greater in ZES-R-treated lesions than in SES-treated lesions (166 ± 73 μm vs. 96 ± 63 μm, respectively, P < 0.001). The percentage of uncovered strut was significantly lower in ZES-R-treated lesions than in SES-treated lesions (4.4 ± 4.8% vs. 10.3 ± 13.2%, respectively, P = 0.05). The percentage of malapposed struts was also significantly lower in ZES-R-treated than in SES-treated lesions (0.1 ± 0.4% vs. 1.5 ± 4.2%, respectively, P = 0.002). Intracoronary thrombus was less frequently detected in ZES-R-treated lesions (4.7% vs. 30.0%, respectively, P = 0.001). ZES-R showed a lower incidence of uncovered or malapposed stent struts and intracoronary thrombus than SES at 9-month follow-up OCT examination. Compared with SES, ZES-R may elicit more favorable vascular responses at the expense of an increased neointimal proliferation.
Full Text
http://link.springer.com/article/10.1007%2Fs10554-011-9943-x
DOI
21858655
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers
Yonsei Authors
Ko, Young Guk(고영국) ORCID logo https://orcid.org/0000-0001-7748-5788
Kim, Byeong Keuk(김병극) ORCID logo https://orcid.org/0000-0003-2493-066X
Kim, Jung Sun(김중선) ORCID logo https://orcid.org/0000-0003-2263-3274
Kim, Jin Sun(김진선)
Shin, Dong Ho(신동호) ORCID logo https://orcid.org/0000-0002-7874-5542
Jang, Yang Soo(장양수) ORCID logo https://orcid.org/0000-0002-2169-3112
Choi, Dong Hoon(최동훈) ORCID logo https://orcid.org/0000-0002-2009-9760
Hong, Myeong Ki(홍명기) ORCID logo https://orcid.org/0000-0002-2090-2031
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/90456
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links