3 642

Cited 0 times in

Thrombus imaging in acute ischaemic stroke using thin-slice unenhanced CT: comparison of conventional sequential CT and helical CT.

DC Field Value Language
dc.contributor.author김응엽-
dc.contributor.author안성수-
dc.date.accessioned2014-12-19T16:49:13Z-
dc.date.available2014-12-19T16:49:13Z-
dc.date.issued2012-
dc.identifier.issn0938-7994-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/90255-
dc.description.abstractOBJECTIVES: Thin-slice helical unenhanced CT can be used for thrombus imaging but increases radiation exposure. Conventional sequential images obtained by multidetector CT can be reconstructed into thin-slice images. The purpose of this study was to evaluate if conventional sequential unenhanced CT images can replace helical unenhanced CT for thrombus imaging. METHODS: Fifty consecutive patients with acute ischaemic stroke underwent both 5-mm conventional sequential unenhanced CT and helical unenhanced CT. Each of the sequential and helical unenhanced CT images was subsequently reconstructed into four 1.25-mm images. Thrombus volumes and HU were measured semi-automatically using both types of unenhanced CT. Thrombus HU ratio (rHU) was calculated using the HU of the contralateral segment. The intraclass correlation coefficient (ICC) and Bland-Altman plots were used to assess measurement agreement. RESULTS: The mean rHUs were 1.47 ± 0.17 for sequential unenhanced CT and 1.47 ± 0.18 helical unenhanced CT (P = 0.542). The mean thrombus volumes were 124.25 ± 125.65 mm(3) and 117.84 ± 124.32 mm(3) on sequential and helical unenhanced CT images, respectively (P = 0.063). Measurement agreement between thrombus volumes from the two unenhanced CT images was high (ICC = 0.981). CONCLUSIONS: Thin-slice unenhanced CT images reconstructed from 5-mm sequential images can replace helical unenhanced CT for thrombus imaging in acute ischaemic stroke. KEY POINTS : • Unenhanced CT is used to evaluate intra-arterial thrombus. • Thrombus HU and volume measurements using sequential or helical CT are comparable. • Conventional sequential images can replace helical CT for thrombus imaging. • Radiation dose for thrombus imaging can be reduced using sequential CT.-
dc.description.statementOfResponsibilityopen-
dc.relation.isPartOfEUROPEAN RADIOLOGY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAged-
dc.subject.MESHCarotid Artery, Internal/pathology-
dc.subject.MESHDiagnostic Imaging/methods-
dc.subject.MESHFemale-
dc.subject.MESHHumans-
dc.subject.MESHImage Processing, Computer-Assisted-
dc.subject.MESHIschemia/pathology*-
dc.subject.MESHMale-
dc.subject.MESHMiddle Aged-
dc.subject.MESHMiddle Cerebral Artery/pathology-
dc.subject.MESHReproducibility of Results-
dc.subject.MESHStroke/diagnosis*-
dc.subject.MESHStroke/pathology-
dc.subject.MESHThrombosis/pathology*-
dc.subject.MESHTomography, Spiral Computed/methods*-
dc.subject.MESHTomography, X-Ray Computed/methods*-
dc.titleThrombus imaging in acute ischaemic stroke using thin-slice unenhanced CT: comparison of conventional sequential CT and helical CT.-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Radiology (영상의학)-
dc.contributor.googleauthorSung Soo Ahn-
dc.contributor.googleauthorEung Yeop Kim-
dc.identifier.doi22653288-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA02234-
dc.contributor.localIdA00832-
dc.relation.journalcodeJ00851-
dc.identifier.eissn1432-1084-
dc.identifier.pmid22653288-
dc.identifier.urlhttp://link.springer.com/article/10.1007%2Fs00330-012-2518-y-
dc.subject.keywordMultidetector CT-
dc.subject.keywordThrombus-
dc.subject.keywordBrain infarction-
dc.subject.keywordThrombolysis-
dc.subject.keywordStroke-
dc.contributor.alternativeNameKim, Eung Yeop-
dc.contributor.alternativeNameAhn, Sung Soo-
dc.contributor.affiliatedAuthorAhn, Sung Soo-
dc.contributor.affiliatedAuthorKim, Eung Yeop-
dc.citation.volume22-
dc.citation.number11-
dc.citation.startPage2392-
dc.citation.endPage2396-
dc.identifier.bibliographicCitationEUROPEAN RADIOLOGY, Vol.22(11) : 2392-2396, 2012-
dc.identifier.rimsid34097-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.