Cited 0 times in

Comparison of optical quality parameters and ocular aberrations after wavefront-guided laser in-situ keratomileusis versus wavefront-guided laser epithelial keratomileusis for myopia

Authors
 Kwanghyun Lee ; Ji Min Ahn ; Tae-im Kim ; Eung Kweon Kim 
Citation
 Graefes Archive for Clinical and Experimental Ophthalmology, Vol.251(9) : 2163~2169, 2013 
Journal Title
 Graefes Archive for Clinical and Experimental Ophthalmology 
ISSN
 0721-832X 
Issue Date
2013
Abstract
BACKGROUND: To compare optical quality, ocular scattering, and higher-order aberrations (HOAs) after laser in-situ keratomileusis (LASIK) versus laser epithelial keratomileusis (LASEK). METHODS: A total of 47 eyes from 47 participants who had undergone LASIK (group I) or LASEK (group II) procedure at least 6 months prior were enrolled. Ocular aberrations and modulation transfer function (MTF) values measured using iTrace, a ray-tracing type aberrometer, were compared to MTF (modulation transfer function) cut-off values, Strehl ratio, and objective indices of scattering obtained using the Objective Quality Analysis System II (OQAS II). RESULTS: There was no significant correlation between the postoperative optical quality parameters and the HOAs between both groups. In group I, the MTF cut-off value was significantly correlated with cylinder refraction (p = 0.037), and the objective scattering index (OSI) was positively correlated with spherical equivalent (p = 0.023). In group II, there was a statistically significant correlation between the OSI and achieved refractive correction (p = 0.001). Regression analysis showed that the OSI was the most significant predictor of MTF cut-off values after refractive surgery. Additionally, MTF values measured by OQAS were significantly lower than those measured by iTrace without correlation. CONCLUSION: Optical quality after refractive surgery may be influenced by not only ocular aberrations but also by scattering. Even though the accuracies of the machines used in this study to measure optical quality have yet to be proven, this study showed limited correlation among the values measured using the two different machines after refractive surgery. Therefore, for more generalized evaluation of visual function after refractive surgery, more advanced optical devices still need to be developed.
URI
http://ir.ymlib.yonsei.ac.kr/handle/22282913/88371
DOI
10.1007/s00417-013-2356-x
Appears in Collections:
1. 연구논문 > 1. College of Medicine > Dept. of Ophthalmology
Yonsei Authors
사서에게 알리기
  feedback
Link
 http://link.springer.com/article/10.1007%2Fs00417-013-2356-x
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse