3 587

Cited 31 times in

Optical coherence tomography analysis of strut coverage in biolimus- and sirolimus-eluting stents: 3-Month and 12-month serial follow-up

DC Field Value Language
dc.contributor.author고영국-
dc.contributor.author김병극-
dc.contributor.author김중선-
dc.contributor.author신동호-
dc.contributor.author장양수-
dc.contributor.author최동훈-
dc.contributor.author홍명기-
dc.date.accessioned2014-12-18T09:32:25Z-
dc.date.available2014-12-18T09:32:25Z-
dc.date.issued2013-
dc.identifier.issn0167-5273-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/88359-
dc.description.abstractBACKGROUND: No randomized studies have been conducted to investigate serial changes in optical coherence tomography (OCT) analyses following implantation of biolimus-A9-eluting stents (BES) and sirolimus-eluting stents (SES). METHODS: A total of 60 patients fulfilling the study criteria were randomly assigned into BES (n=30) and SES (n=30) implantation groups. Serial OCT evaluation at post-procedure, 3- and 12-month follow-up was performed in 46 patients [BES (n=22) and SES (n=24)]. OCT analyses were compared according to the type of stents and the follow-up time intervals. The percentage of uncovered struts was defined as the ratio of uncovered struts to total struts in all cross-sections. The primary endpoint was the percentage change (Δ) of uncovered struts in the 3- and 12-month follow-up samples. RESULTS: The percentage of uncovered struts at the 3-month time period was not significantly different in the BES and SES groups; the median value (interquartile range) was 14.7% (0.0-23.4) versus 8.6% (0.7-21.5) (p=0.98), respectively. However, OCT at the 12-month follow-up showed a significantly lower percentage of uncovered struts [2.6% (0.8-5.6) versus 6.2% (1.7-14.7), (p=0.028), respectively] without significant difference of neointimal thickness. BES showed a greater reduction of percentage Δ of uncovered struts from 3-12 months than that of SES [-17.2±14.5% versus -7.7±16.3%, respectively (p=0.043)]. CONCLUSIONS: Both drug-eluting stents showed a high percentage of incomplete strut coverage at 3 months. However, BES showed a significantly lower percentage of uncovered struts at 12 months compared to that of SES. This was achieved by superior strut coverage from 3 to 12 months.-
dc.description.statementOfResponsibilityopen-
dc.relation.isPartOfINTERNATIONAL JOURNAL OF CARDIOLOGY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAntineoplastic Agents, Phytogenic/pharmacology-
dc.subject.MESHCoronary Angiography-
dc.subject.MESHCoronary Artery Disease/diagnosis-
dc.subject.MESHCoronary Artery Disease/surgery*-
dc.subject.MESHCoronary Vessels/pathology*-
dc.subject.MESHCoronary Vessels/surgery-
dc.subject.MESHDrug-Eluting Stents*-
dc.subject.MESHFemale-
dc.subject.MESHFollow-Up Studies-
dc.subject.MESHHumans-
dc.subject.MESHMale-
dc.subject.MESHMiddle Aged-
dc.subject.MESHPaclitaxel/pharmacology*-
dc.subject.MESHProspective Studies-
dc.subject.MESHProsthesis Design-
dc.subject.MESHReproducibility of Results-
dc.subject.MESHSirolimus/analogs & derivatives*-
dc.subject.MESHSirolimus/pharmacology-
dc.subject.MESHTime Factors-
dc.subject.MESHTomography, Optical Coherence/methods*-
dc.subject.MESHTreatment Outcome-
dc.subject.MESHTunica Intima/pathology-
dc.titleOptical coherence tomography analysis of strut coverage in biolimus- and sirolimus-eluting stents: 3-Month and 12-month serial follow-up-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Internal Medicine (내과학)-
dc.contributor.googleauthorByeong-Keuk Kim-
dc.contributor.googleauthorMyeong-Ki Hong-
dc.contributor.googleauthorDong-Ho Shin-
dc.contributor.googleauthorJung-Sun Kim-
dc.contributor.googleauthorYoung-Guk Ko-
dc.contributor.googleauthorDonghoon Choi-
dc.contributor.googleauthorYangsoo Jang-
dc.identifier.doi10.1016/j.ijcard.2013.07.160-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA00127-
dc.contributor.localIdA00493-
dc.contributor.localIdA00961-
dc.contributor.localIdA02097-
dc.contributor.localIdA03448-
dc.contributor.localIdA04053-
dc.contributor.localIdA04391-
dc.relation.journalcodeJ01093-
dc.identifier.eissn1874-1754-
dc.identifier.pmid23932862-
dc.identifier.urlhttp://www.sciencedirect.com/science/article/pii/S0167527313013855-
dc.subject.keywordCoronary artery disease-
dc.subject.keywordDrug-eluting stent-
dc.subject.keywordOptical coherence tomography-
dc.contributor.alternativeNameKo, Young Guk-
dc.contributor.alternativeNameKim, Byeong Keuk-
dc.contributor.alternativeNameKim, Jung Sun-
dc.contributor.alternativeNameShin, Dong Ho-
dc.contributor.alternativeNameJang, Yang Soo-
dc.contributor.alternativeNameChoi, Dong Hoon-
dc.contributor.alternativeNameHong, Myeong Ki-
dc.contributor.affiliatedAuthorKo, Young Guk-
dc.contributor.affiliatedAuthorKim, Byeong Keuk-
dc.contributor.affiliatedAuthorKim, Jung Sun-
dc.contributor.affiliatedAuthorShin, Dong Ho-
dc.contributor.affiliatedAuthorJang, Yang Soo-
dc.contributor.affiliatedAuthorChoi, Dong Hoon-
dc.contributor.affiliatedAuthorHong, Myeong Ki-
dc.rights.accessRightsnot free-
dc.citation.volume168-
dc.citation.number5-
dc.citation.startPage4617-
dc.citation.endPage4623-
dc.identifier.bibliographicCitationINTERNATIONAL JOURNAL OF CARDIOLOGY, Vol.168(5) : 4617-4623, 2013-
dc.identifier.rimsid32459-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.