2 790

Cited 3 times in

Use of a Silicone Penrose Drain to Protect Incised Skin Edges During Thyroid Surgery

Authors
 Yong Sang Lee  ;  Bup Woo Kim  ;  Hang-Seok Chang  ;  Cheong Soo Park 
Citation
 SURGICAL INNOVATION, Vol.20(4) : 1-2, 2013 
Journal Title
SURGICAL INNOVATION
ISSN
 1553-3506 
Issue Date
2013
MeSH
Dermatologic Surgical Procedures/instrumentation* ; Dermatologic Surgical Procedures/methods ; Drainage/instrumentation* ; Drainage/methods ; Humans ; Neck/pathology ; Neck/surgery ; Silicones/therapeutic use* ; Skin/pathology ; Thyroidectomy/instrumentation* ; Thyroidectomy/methods
Keywords
endocrine surgery ; surgical oncology ; thyroid surgery
Abstract
Acceptable wound cosmesis is an important issue in thyroidectomy. We introduce a simple, economical and effective method of preventing traction and thermal damage to the incised skin edges during thyroidectomy.