Aged ; Aged, 80 and over ; Aneurysm, Ruptured/diagnosis ; Aneurysm, Ruptured/therapy* ; Balloon Occlusion/instrumentation* ; Catheters* ; Cerebral Angiography ; Equipment Design ; Female ; Humans ; Intracranial Aneurysm/diagnosis ; Intracranial Aneurysm/therapy* ; Male ; Middle Aged ; Retrospective Studies ; Stents ; Treatment Outcome
Keywords
Balloon ; Coil embolization ; Intracranial aneurysm
Abstract
OBJECTIVE:
A new double-lumen balloon catheter was being developed for the treatment of cerebral aneurysms. The purpose of this study is to report our initial experience of a double-lumen balloon catheter for the treatment of wide-necked aneurysms.
MATERIALS AND METHODS:
Seventeen patients (mean age, 63 years; range, 45-80 years) with wide-necked, with or without a branch-incorporated aneurysms, (10 ruptured and 9 unruptured) were treated with balloon-assisted coil embolization using a double-lumen balloon catheter (Scepter C™ or Scepter XC™) for 7 months after being introduced to our country. Locations of the aneurysms were posterior communicating artery (n = 7), anterior communicating artery or A2 (n = 7), middle cerebral artery (MCA) bifurcation (n = 3), basilar artery tip (n = 1) and anterior choroidal artery (n = 1). The initial clinical and angiographic outcomes were retrospectively evaluated.
RESULTS:
Coil embolization was successfully completed in all 19 aneurysms, resulting in complete occlusions (n = 18) or residual neck (n = 1). In one procedure, a thrombus formation was detected at the neck portion of the ruptured MCA bifurcation aneurysm near to the end of the procedure. It was completely resolved with an intra-arterial infusion of Glycoprotein IIb/IIIa inhibitor (Tirofiban, 1.0 mg) without any clinical sequela. There were no treatment-related events in the remaining 18 aneurysms. At discharge, functional neurological state improved in 11 patients (10 patients with ruptured aneurysm and 1 with unruptured aneurysm presenting with mass symptoms) and 6 patients with unruptured aneurysms had no newly developed symptoms.
CONCLUSION:
In this preliminary case series, the newly developed double-lumen Scepter balloon appears to be a safe and convenient device for coil embolization of wide-necked aneurysms.
Files in This Item:
T201302998.pdf Download
DOI
10.3348/kjr.2013.14.5.832
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers
Yonsei Authors
Kim, Dong Ik(김동익)
Kim, Dong Joon(김동준) ORCID logo https://orcid.org/0000-0002-7035-087X
Kim, Byung Moon(김병문) ORCID logo https://orcid.org/0000-0001-8593-6841
Suh, Sang Hyun(서상현) ORCID logo https://orcid.org/0000-0002-7098-4901
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/87740
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links