Cited 17 times in

Inter-study reproducibility of cardiovascular magnetic resonance tagging

Title
Inter-study reproducibility of cardiovascular magnetic resonance tagging
Authors
Sirisha Donekal;Bharath Ambale-Venkatesh;Joao A C Lima;David A Bluemke;Ahmed A Harouni;Raymond Yan;Veronica Fernandes;Eui Young Choi;Colin O Wu;Seth Berkowitz
Issue Date
2013
Journal Title
Journal of Cardiovascular Magnetic Resonance
ISSN
1097-6647
Citation
Journal of Cardiovascular Magnetic Resonance, Vol.15(1) : 37, 2013
Abstract
BACKGROUND: The aim of this study is to determine the test-retest reliability of the measurement of regional myocardial function by cardiovascular magnetic resonance (CMR) tagging using spatial modulation of magnetization. METHODS: Twenty-five participants underwent CMR tagging twice over 12 +/- 7 days. To assess the role of slice orientation on strain measurement, two healthy volunteers had a first exam, followed by image acquisition repeated with slices rotated +/-15 degrees out of true short axis, followed by a second exam in the true short axis plane. To assess the role of slice location, two healthy volunteers had whole heart tagging. The harmonic phase (HARP) method was used to analyze the tagged images. Peak midwall circumferential strain (Ecc), radial strain (Err), Lambda 1, Lambda 2, and Angle alpha were determined in basal, mid and apical slices. LV torsion, systolic and early diastolic circumferential strain and torsion rates were also determined. RESULTS: LV Ecc and torsion had excellent intra-, interobserver, and inter-study intra-class correlation coefficients (ICC range, 0.7 to 0.9). Err, Lambda 1, Lambda 2 and angle had excellent intra- and interobserver ICC than inter-study ICC. Angle had least inter-study reproducibility. Torsion rates had superior intra-, interobserver, and inter-study reproducibility to strain rates. The measurements of LV Ecc were comparable in all three slices with different short axis orientations (standard deviation of mean Ecc was 0.09, 0.18 and 0.16 at basal, mid and apical slices, respectively). The mean difference in LV Ecc between slices was more pronounced in most of the basal slices compared to the rest of the heart. CONCLUSIONS: Intraobserver and interobserver reproducibility of all strain and torsion parameters was excellent. Inter-study reproducibility of CMR tagging by SPAMM varied between different parameters as described in the results above and was superior for Ecc and LV torsion. The variation in LV Ecc measurement due to altered slice orientation is negligible compared to the variation due to slice location.Trial registration: This trial is registered as NCT00005487 at National Heart, Lung and Blood institute.
URI

http://ir.ymlib.yonsei.ac.kr/handle/22282913/87467
DOI
10.1186/1532-429X-15-37
Appears in Collections:
1. 연구논문 > 1. College of Medicine > Dept. of Internal Medicine
Yonsei Authors
사서에게 알리기
  feedback
Files in This Item:
T201302603.pdfDownload
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse