Comparison of Preoperative and Postoperative Ocular Biometry in Eyes with Phakic Intraocular Lens Implantations

Authors
 Joo Youn Shin  ;  Jae Bum Lee  ;  Kyoung Yul Seo  ;  Eung Kweon Kim  ;  Tae-im Kim 
Citation
 YONSEI MEDICAL JOURNAL, Vol.54(5) : 1259-1265, 2013 
Journal Title
YONSEI MEDICAL JOURNAL
ISSN
 0513-5796 
Issue Date
2013
MeSH
Adult ; Biometry ; Eye/diagnostic imaging ; Female ; Humans ; Interferometry ; Lens Implantation, Intraocular/adverse effects* ; Male ; Middle Aged ; Postoperative Complications ; Ultrasonography
Keywords
Biometry ; anterior chamber depth ; axial length ; phakic intraocular lenses
Abstract
PURPOSE:
To compare preoperative and postoperative ocular biometry in patients with iris-fixated phakic intraocular lens (pIOLs): Artisan and Artiflex.
MATERIALS AND METHODS:
This study included 40 eyes with Artisan and 36 eyes with Artiflex pIOL implants. Anterior chamber depth (ACD) and axial length (AL) were measured by applanation ultrasonography (A-scan) and partial coherence interferometry (IOLMaster) preoperatively and 3 months after pIOL implantation.
RESULTS:
ACD measurements after Artisan or Artiflex pIOL implantation were smaller than preoperative measurements. Specifically, the difference after Artisan pIOL implantation was -1.07 ± 0.17 mm by A-scan and -0.08 ± 0.08 mm by IOLMaster. The difference after Artiflex pIOL implantation was -1.31 ± 0.15 mm by A-scan and -0.05 ± 0.07 mm by IOLMaster. After Artisan pIOL implantation, differences in AL measurements by A-scan were insignificant (difference: -0.03 ± 0.15 mm), whereas postoperative AL measurements by IOLMaster were significantly longer than preoperative measurements (difference: 0.12 ± 0.07 mm). After Artiflex pIOL implantation, AL measurements by both A-scan and IOLMaster were significantly longer than preoperative measurements (difference: 0.09 ± 0.16 mm by A-scan and 0.07 ± 0.10 mm by IOLMaster). In the Artiflex group, differences in AL measurements by A-scan correlated with the central thickness of the Artiflex pIOL.
CONCLUSION:
ACD and AL measurements were influenced by iris-fixated phakic IOL implantation.
Files in This Item:
T201302464.pdf Download
DOI
10.3349/ymj.2013.54.5.1259
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Ophthalmology (안과학교실) > 1. Journal Papers
Yonsei Authors
Kim, Eung Kweon(김응권) ORCID logo https://orcid.org/0000-0002-1453-8042
Kim, Tae-Im(김태임) ORCID logo https://orcid.org/0000-0001-6414-3842
Seo, Kyoung Yul(서경률) ORCID logo https://orcid.org/0000-0002-9855-1980
Shin, Joo Youn(신주연) ORCID logo https://orcid.org/0000-0003-4543-477X
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/87396
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links