Cited 0 times in

서로 다른 세 가지 비구면 일체형 인공수정체 삽입 수술 후 임상 결과의 비교

Other Titles
 Comparisons of Clinical Results after Implantation of Three Aspheric Intraocular Lenses 
Authors
 최영준 ; 한경은 ; 김태임 ; 김응권 ; 서경률 ; 이형근 ; 정세환 ; 안지민 
Citation
 Journal of the Korean Ophthalmological Society (대한안과학회지), Vol.54(2) : 251~256, 2013 
Journal Title
 Journal of the Korean Ophthalmological Society (대한안과학회지) 
ISSN
 0378-6471 
Issue Date
2013
Abstract
Purpose To compare the clinical results after implantation of three one-piece aspheric lenses, Acrysof IQ SN60WF, Tecnis 1-piece ZCB00 and the newly developed IOL HOYA AF-1 NY-60. Methods In total 66 eyes, one of three one-piece aspheric lenses, Acrysof IQ SN60WF, TECNIS 1-piece ZCB00 or HOYA AF-1 NY-60 was implanted after cataract extraction. Best corrected visual acuity (BCVA) and uncorrected visual acuity (UCVA) were assessed at postoperative 3 months. Total spherical aberration, high order aberration and modulation transfer function of 5.0 mm pupil size zone were evaluated. Results There were no significant differences of UCVA, BCVA, the accuracy of postoperative refractive power and modulation transfer function among three groups. High order aberrations of the entire eye and internal optics showed almost no significant differences except some aberration values. Conclusions The newly developed intraocular lens, HOYA AF-1 NY-60 showed almost equal clinical results in comparison with Acrysof IQ SN60WF and TECNIS 1-piece ZCB00.
URI
http://ir.ymlib.yonsei.ac.kr/handle/22282913/86889
DOI
10.3341/jkos.2013.54.2.251
Appears in Collections:
1. 연구논문 > 1. College of Medicine > Dept. of Ophthalmology
Yonsei Authors
사서에게 알리기
  feedback
Files in This Item:
T201301589.pdfDownload
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse