2 525

Cited 45 times in

Meibomian gland dysfunction in longstanding prosthetic eye wearers

Authors
 Sun Young Jang  ;  Sang Yeul Lee  ;  Jin Sook Yoon 
Citation
 BRITISH JOURNAL OF OPHTHALMOLOGY, Vol.97(4) : 398-402, 2013 
Journal Title
BRITISH JOURNAL OF OPHTHALMOLOGY
ISSN
 0007-1161 
Issue Date
2013
MeSH
Adolescent ; Adult ; Aged ; Eye Enucleation ; Eye Evisceration ; Eye, Artificial/adverse effects* ; Eyelid Diseases/diagnosis ; Eyelid Diseases/etiology* ; Female ; Fourier Analysis ; Humans ; Male ; Meibomian Glands/diagnostic imaging ; Meibomian Glands/pathology* ; Middle Aged ; Orbital Implants* ; Radiography ; Surveys and Questionnaires ; Tears/physiology ; Tomography, Optical Coherence ; Young Adult
Keywords
Adolescent ; Adult ; Aged ; Eye Enucleation ; Eye Evisceration ; Eye, Artificial/adverse effects* ; Eyelid Diseases/diagnosis ; Eyelid Diseases/etiology* ; Female ; Fourier Analysis ; Humans ; Male ; Meibomian Glands/diagnostic imaging ; Meibomian Glands/pathology* ; Middle Aged ; Orbital Implants* ; Radiography ; Surveys and Questionnaires ; Tears/physiology ; Tomography, Optical Coherence ; Young Adult
Abstract
PURPOSE:
To determine whether meibomian gland dysfunction (MGD) is a possible cause of ocular discomfort in patients wearing an ocular prosthesis, with the paired normal eye used as a control.
METHODS:
Thirty consecutive patients with a unilateral ocular prosthesis completed a questionnaire designed to identify MGD-related ocular symptoms. Both eyelids of each patient underwent slit lamp examination, meibography imaging, and Fourier-domain (FD) optical coherence tomography (OCT) scanning. Intra-individual comparison of main outcome measures between the eyelids of a prosthetic eye and paired normal eyelids was performed using Wilcoxon signed-rank test. A linear mixed model was used to investigate an association between ocular symptoms and condition of meibomian gland/tear parameters.
RESULTS:
The eyelids with an ocular prosthesis exhibited significantly higher scores for ocular symptoms, lid margin abnormality, meibomian gland expression, and meibography compared to the normal eyelids (p<0.01 for all scores). Tear parameters in the eyelid of a prosthetic eye, assessed with FD OCT, were significantly lower than those of the normal eyelid (p<0.01 for all scores except tear meniscus angle). The ocular symptom score was significantly positively correlated with the meibography score and negatively correlated with tear parameters (p<0.01 for all parameters, linear mixed model).
CONCLUSIONS:
Compared to paired normal eyelids, the eyelids with an ocular prosthesis exhibited significant signs of MGD. These results indicate that clinical assessment and management recommendations for MGD may benefit patients with prosthetic eyes, especially those with ocular discomfort.
Full Text
http://bjo.bmj.com/content/97/4/398.long
DOI
10.1136/bjophthalmol-2012-302404
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Ophthalmology (안과학교실) > 1. Journal Papers
Yonsei Authors