Usefulness of a Cook® airway exchange catheter in laryngeal mask airway-guided fiberoptic intubation in a neonate with Pierre Robin syndrome -A case report-

DC Field Value Language
dc.contributor.author김지은-
dc.contributor.author박윤곤-
dc.contributor.author소사라-
dc.contributor.author최은경-
dc.date.accessioned2014-12-18T08:32:17Z-
dc.date.available2014-12-18T08:32:17Z-
dc.date.issued2013-
dc.identifier.issn2005-6419-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/86494-
dc.description.abstractThe case of a 33-day-old boy with Pierre Robin syndrome using a Cook® airway exchange catheter in laryngeal mask airway-guided fiberoptic intubation is presented. After induction with sevoflurane, classical reusable laryngeal mask airway (LMA) #1 was inserted and ultrathin fiberoptic bronchoscope (FOB) was passed through. A Cook® airway exchange catheter (1.6 mm ID, 2.7 mm OD) was passed through the LMA under the guidance of the FOB but failed to enter the trachea despite many trials. Then, an endotracheal tube (3.0 mm ID) was mounted on the FOB and railroaded over the FOB. After successful intubation, the Cook® airway exchange catheter was placed in the midtrachea through the lumen of the endotracheal tube. Even though the tracheal tube was accidentally displaced out of the trachea during LMA removal, the endotracheal tube could be easily railroaded over the airway exchange catheter.-
dc.description.statementOfResponsibilityopen-
dc.relation.isPartOfKOREAN JOURNAL OF ANESTHESIOLOGY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.titleUsefulness of a Cook® airway exchange catheter in laryngeal mask airway-guided fiberoptic intubation in a neonate with Pierre Robin syndrome -A case report--
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Anesthesiology (마취통증의학)-
dc.contributor.googleauthorEun Kyeong Choi-
dc.contributor.googleauthorJi Eun Kim-
dc.contributor.googleauthorSa Rah Soh-
dc.contributor.googleauthorChang Kyun Kim-
dc.contributor.googleauthorWyun Kon Park-
dc.identifier.doi10.4097/kjae.2013.64.2.168-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA01593-
dc.contributor.localIdA01960-
dc.contributor.localIdA04146-
dc.contributor.localIdA00990-
dc.relation.journalcodeJ01963-
dc.identifier.eissn2005-7563-
dc.identifier.pmidAirway exchange catheter ; Fiberoptic intubation ; Laryngeal mask airway ; Pierre robin syndrome-
dc.subject.keywordAirway exchange catheter-
dc.subject.keywordFiberoptic intubation-
dc.subject.keywordLaryngeal mask airway-
dc.subject.keywordPierre robin syndrome-
dc.contributor.alternativeNameKim, Ji Eun-
dc.contributor.alternativeNamePark, Wyun Kon-
dc.contributor.alternativeNameSoh, Sa Rah-
dc.contributor.alternativeNameChoi, Eun Kyeong-
dc.contributor.affiliatedAuthorPark, Wyun Kon-
dc.contributor.affiliatedAuthorSoh, Sa Rah-
dc.contributor.affiliatedAuthorChoi, Eun Kyeong-
dc.contributor.affiliatedAuthorKim, Ji Eun-
dc.rights.accessRightsfree-
dc.citation.volume64-
dc.citation.number2-
dc.citation.startPage168-
dc.citation.endPage171-
dc.identifier.bibliographicCitationKOREAN JOURNAL OF ANESTHESIOLOGY, Vol.64(2) : 168-171, 2013-
dc.identifier.rimsid29013-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Anesthesiology and Pain Medicine (마취통증의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.