25 60

Cited 0 times in

Diagnostic performance with and without artificial intelligence assistance in real-world screening mammography

Authors
 Si Eun Lee  ;  Hanpyo Hong  ;  Eun-Kyung Kim 
Citation
 EUROPEAN JOURNAL OF RADIOLOGY OPEN, Vol.12 : 1005451, 2024-01 
Journal Title
EUROPEAN JOURNAL OF RADIOLOGY OPEN
Issue Date
2024-01
Keywords
Artificial intelligence ; Breast cancer ; Diagnosis, Computer-assisted ; Digital mammography
Abstract
Purpose: To evaluate artificial intelligence-based computer-aided diagnosis (AI-CAD) for screening mammography, we analyzed the diagnostic performance of radiologists by providing and withholding AI-CAD results alternatively every month.

Methods: This retrospective study was approved by the institutional review board with a waiver for informed consent. Between August 2020 and May 2022, 1819 consecutive women (mean age 50.8 ± 9.4 years) with 2061 screening mammography and ultrasound performed on the same day in a single institution were included. Radiologists interpreted screening mammography in clinical practice with AI-CAD results being provided or withheld alternatively by month. The AI-CAD results were retrospectively obtained for analysis even when withheld from radiologists. The diagnostic performances of radiologists and stand-alone AI-CAD were compared and the performances of radiologists with and without AI-CAD assistance were also compared by cancer detection rate, recall rate, sensitivity, specificity, accuracy and area under the receiver-operating-characteristics curve (AUC).

Results: Twenty-nine breast cancer patients and 1790 women without cancers were included. Diagnostic performances of the radiologists did not significantly differ with and without AI-CAD assistance. Radiologists with AI-CAD assistance showed the same sensitivity (76.5%) and similar specificity (92.3% vs 93.8%), AUC (0.844 vs 0.851), and recall rates (8.8% vs. 7.4%) compared to standalone AI-CAD. Radiologists without AI-CAD assistance showed lower specificity (91.9% vs 94.6%) and accuracy (91.5% vs 94.1%) and higher recall rates (8.6% vs 5.9%, all p < 0.05) compared to stand-alone AI-CAD.

Conclusion: Radiologists showed no significant difference in diagnostic performance when both screening mammography and ultrasound were performed with or without AI-CAD assistance for mammography. However, without AI-CAD assistance, radiologists showed lower specificity and accuracy and higher recall rates compared to stand-alone AI-CAD.
Files in This Item:
T202400600.pdf Download
DOI
10.1016/j.ejro.2023.100545
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers
Yonsei Authors
Kim, Eun-Kyung(김은경) ORCID logo https://orcid.org/0000-0002-3368-5013
Lee, Si Eun(이시은) ORCID logo https://orcid.org/0000-0002-3225-5484
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/198786