0 97

Cited 0 times in

Automatic measurement of mouse visual acuity based on optomotor response: SKY optomotry

Authors
 So Yeon Ahn  ;  Eun Hye Jung  ;  Hyunmin Ahn  ;  Jihei Sara Lee  ;  Jeong Hyeon Bak  ;  Eun-do Kim  ;  Ja-Hyun Song  ;  Hae-Sol Shin  ;  Munkhdelger Jamiyansharav  ;  Kyoung Yul Seo 
Citation
 LABORATORY ANIMALS, Vol.57(4) : 412-423, 2023-08 
Journal Title
 LABORATORY ANIMALS 
Issue Date
2023-08
MeSH
Animals ; Evoked Potentials, Visual* ; Mice ; Mice, Inbred C57BL ; Rodentia* ; Visual Acuity
Keywords
Automation ; mouse ; optometry ; optomotor response ; visual acuity ; visual performance
Abstract
In the field of visual science study using rodents, several assessment methods have been developed for measuring visual function. However, methods such as electroretinograms tests, visual evoked potentials tests and maze tests have limitations in that they measure function of only a specific type of cells, are difficult to quantify or require sufficient training time. The method which uses an optokinetic reflex and optomotor response, a compensatory eye and head movement in response to changes in the visual scene, became the most widely used method. However, this method requires highly trained experimenters and is time consuming. We showed that measured visual acuity values are significantly different between beginner and expert. Here we suggest an automated optometry program, 'SKY optomotry', which automatically tracks rodents' optomotor response to overcome subjectivity and the lengthy scoring procedure of the existing method. To evaluate the performance of SKY optomotry using 8-12-week-old C57BL/6 mice we compared the binomial decision of SKY optomotry with a skilled expert, and the area under the curve of SKY optomotry was 0.845. Comparing the final visual acuity, the intraclass correlation coefficient value between SKY optomotry and an expert was 0.860 (95% confidence interval (CI) 0.709-0.928), whereas that between an expert and a beginner was 0.642 (95% CI 0.292-0.811). SKY optomotry showed an excellent level of performance with good inter-rater agreements based on the visual acuity measured by an expert. With the use of our application, researchers will be able to test an experimental animal's eyesight more accurately while saving time on specialized training.
Full Text
https://journals.sagepub.com/doi/10.1177/00236772221148576
DOI
10.1177/00236772221148576
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Ophthalmology (안과학교실) > 1. Journal Papers
Yonsei Authors
Seo, Kyoung Yul(서경률) ORCID logo https://orcid.org/0000-0002-9855-1980
Ahn, Hyunmin(안현민)
Lee, Jihei Sara(이지혜)
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/197533
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links