0 133

Cited 0 times in

Volumetric Absorptive Microsampling for the Therapeutic Drug Monitoring of Everolimus in Patients Who Have Undergone Liver Transplant

Authors
 Seungji Yoo  ;  Giseob Kim  ;  Soyeon Kim  ;  Jungeun Ha  ;  Beom Sik Cho  ;  Dong Jin Joo  ;  Jangik I Lee 
Citation
 THERAPEUTIC DRUG MONITORING, Vol.45(2) : 223-228, 2023-04 
Journal Title
THERAPEUTIC DRUG MONITORING
ISSN
 0163-4356 
Issue Date
2023-04
MeSH
Blood Specimen Collection / methods ; Chromatography, Liquid / methods ; Dried Blood Spot Testing / methods ; Drug Monitoring / methods ; Everolimus* / therapeutic use ; Humans ; Liver Transplantation*
Abstract
Background: Therapeutic drug monitoring (TDM) of everolimus is required to prevent organ rejection in patients who have undergone transplant. Volumetric absorptive microsampling (VAMS) is a minimally invasive method for accurately collecting a small amount of blood from a patient's fingers. This study aimed to assess the applicability of VAMS for TDM of everolimus.

Methods: VAMS and venous blood samples were collected from 45 liver transplant recipients who had been receiving stable everolimus doses for at least 7 days. Whole blood everolimus concentrations were measured using ultrahigh performance liquid chromatography with tandem mass spectrometry. Deming regression and Bland–Altman analysis were performed to compare everolimus concentrations measured using VAMS (CVAMS) and venous blood samples (CIV). The regression coefficient (r2) between CVAMS and CIV was calculated using a linear regression. The effects of the hematocrit and blood sampling time on the difference between CVAMS and CIV were investigated.

Results: Thirty-two participants were included in the final analysis. The Deming regression line was CIV = 1.04 × CVAMS + 0.55 [95% confidence interval (CI) of slope, 0.91–1.18; 95% CI of intercept, −0.05 to 1.16]. CVAMS and CIV were strongly correlated (r2 = 0.92), with no proportional or constant bias. The mean difference between CVAMS and CIV was −0.79 ng/mL, with the 95% limit of agreement ranging from −2.55 to 0.97 ng/mL in a Bland–Altman plot. No effect of the hematocrit or blood sampling time was observed.

Conclusions: VAMS and venous blood sampling showed good agreement for the measurement of whole blood everolimus concentrations. Less invasive VAMS can substitute for more invasive venous blood sampling in the TDM of everolimus in liver transplant patients.
Full Text
https://journals.lww.com/drug-monitoring/Fulltext/2023/04000/Volumetric_Absorptive_Microsampling_for_the.13.aspx
DOI
10.1097/ftd.0000000000001033
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Surgery (외과학교실) > 1. Journal Papers
Yonsei Authors
Joo, Dong Jin(주동진) ORCID logo https://orcid.org/0000-0001-8405-1531
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/195287
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links