134 222

Cited 5 times in

Anterior Ocular Biometrics Using Placido-scanning-slit System, Rotating Scheimpflug Tomography, and Swept-source Optical Coherence Tomography

DC Field Value Language
dc.contributor.author김응권-
dc.contributor.author김태임-
dc.contributor.author서경률-
dc.contributor.author전익현-
dc.date.accessioned2022-12-22T02:11:53Z-
dc.date.available2022-12-22T02:11:53Z-
dc.date.issued2022-06-
dc.identifier.issn1011-8942-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/191491-
dc.description.abstractPurpose: To compare anterior biometry measurements using placido-scanning-slit topography, rotating Scheimpflug tomography, and swept-source optical coherence tomography. Methods: A retrospective review consisted of 80 eyes of 49 participants who underwent anterior chamber depth (ACD), central corneal thickness (CCT), and keratometry examination on the same day. We used placido-scanning-slit topography (ORBscan II), rotating Scheimpflug tomography (Pentacam HR), and swept-source optical coherence tomography (CASIA SS1000). The intraclass correlation coefficients and Bland-Altman plots were used to evaluate the agreement and differences between measurements. Results: The mean ACD values were 2.88 ± 0.43, 2.82 ± 0.50, and 2.68 ± 0.44 mm; and the mean CCT values were 536.96 ± 31.19, 543.79 ± 31.04, and 561.41 ± 32.60 μm; and the mean keratometry (Km) were 43.81 ± 1.69, 43.81 ± 1.77, and 44.65 ± 1.95 diopters; as measured by CASIA SS-1000, Pentacam HR, and ORBscan II, respectively. Among the three devices, ACD was deepest to shallowest in the order of CASIA SS-1000, Pentacam HR, and ORBscan II (p < 0.05). The CCT was thickest to thinnest in the order of ORBscan II, Pentacam HR, and CASIA SS-1000 (p < 0.05). No significant differences in Km values were examined between CASIA SS-1000 and Pentacam HR, whereas ORBscan II overestimated Km with a statistically significant difference compared to the other two devices. Conclusions: High level of agreement was found between CASIA SS-1000 and Pentacam HR for anterior parameters, including ACD, CCT, and Km, suggesting interchangeability. However, ORBscan II measurements differed considerably with the measurements obtained from the other two devices; therefore, it should not be used interchangeably. However, further studies with repeatability test should be considered in order to elucidate the reliability of each device.-
dc.description.statementOfResponsibilityopen-
dc.languageEnglish-
dc.publisherKJO-
dc.relation.isPartOfKorean Journal of Ophthalmology-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.subject.MESHBiometry* / methods-
dc.subject.MESHCornea / diagnostic imaging-
dc.subject.MESHCorneal Topography / methods-
dc.subject.MESHHumans-
dc.subject.MESHProspective Studies-
dc.subject.MESHReproducibility of Results-
dc.subject.MESHTomography, Optical Coherence* / methods-
dc.titleAnterior Ocular Biometrics Using Placido-scanning-slit System, Rotating Scheimpflug Tomography, and Swept-source Optical Coherence Tomography-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Ophthalmology (안과학교실)-
dc.contributor.googleauthorSoyoung Ryu-
dc.contributor.googleauthorSook Hyun Yoon-
dc.contributor.googleauthorIkhyun Jun-
dc.contributor.googleauthorKyoung Yul Seo-
dc.contributor.googleauthorEung Kweon Kim-
dc.contributor.googleauthorTae-Im Kim-
dc.identifier.doi10.3341/kjo.2021.0120-
dc.contributor.localIdA00831-
dc.contributor.localIdA01080-
dc.contributor.localIdA01870-
dc.contributor.localIdA03541-
dc.relation.journalcodeJ02931-
dc.identifier.eissn2092-9382-
dc.identifier.pmid35527529-
dc.subject.keywordAnterior-
dc.subject.keywordAnterior eye segment-
dc.subject.keywordPlacido-scanning-slit-
dc.subject.keywordScheimpflug camera-
dc.subject.keywordSwept source optical coherence tomography-
dc.contributor.alternativeNameKim, Eung Kweon-
dc.contributor.affiliatedAuthor김응권-
dc.contributor.affiliatedAuthor김태임-
dc.contributor.affiliatedAuthor서경률-
dc.contributor.affiliatedAuthor전익현-
dc.citation.volume36-
dc.citation.number3-
dc.citation.startPage264-
dc.citation.endPage273-
dc.identifier.bibliographicCitationKorean Journal of Ophthalmology, Vol.36(3) : 264-273, 2022-06-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Ophthalmology (안과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.