411 569

Cited 7 times in

Comparison of Transcatheter Aortic Valve Replacement between Self-Expanding versus Balloon-Expandable Valves in Patients with Small Aortic Annulus

Authors
 Yong Joon Lee  ;  Seung Jun Lee  ;  Sung Jin Hong  ;  Chi Young Shim  ;  Chul Min Ahn  ;  Jung Sun Kim  ;  Byeong Keuk Kim  ;  Geu Ru Hong  ;  Young Guk Ko  ;  Donghoon Choi  ;  Yangsoo Jang  ;  Myeong Ki Hong 
Citation
 KOREAN CIRCULATION JOURNAL, Vol.51(3) : 222-231, 2021-03 
Journal Title
KOREAN CIRCULATION JOURNAL
ISSN
 1738-5520 
Issue Date
2021-03
Keywords
Aortic valve stenosis ; Transcatheter aortic valve replacement
Abstract
Background and objectives: Transcatheter aortic valve replacement (TAVR) has been reported as a good alternative for surgical aortic valve replacement in patients with small aortic annulus. Head-to-head comparisons of different transcatheter aortic valves in these patients are insufficient. We compared the outcomes after TAVR between two different types of recent transcatheter aortic valves (self-expanding vs. balloon-expandable) in patients with small aortic annulus.

Methods: A total of 70 patients with severe aortic stenosis and small annulus (mean diameter ≤23 mm or minimal diameter ≤21 mm on computed tomography) underwent TAVR with either a self-expanding valve with supra-annular location (n=45) or a balloon-expandable valve with intra-annular location (n=25). The echocardiographic hemodynamic parameters after TAVR and 1-year follow-up were compared.

Results: Between the self-expanding and balloon-expandable valve-treated patients, the clinical outcomes including permanent pacemaker implantation (11.1% vs. 8.0%), acute kidney injury stage 2 or 3 (4.4% vs. 4.0%), and major vascular complication (4.4% vs. 0.0%) were similar without all-cause mortality, stroke, and life-threatening bleeding during 30-day follow-up. Compared with the balloon-expandable valve-treated patients, the self-expanding valve-treated patients presented larger effective orifice area (EOA) (1.46±0.28 vs. 1.75±0.42 cm², p=0.002) and indexed EOA (0.95±0.21 vs. 1.18±0.28 cm²/m², p=0.001), whereas mean aortic valve gradient (11.7±2.9 vs. 8.9±5.2 mmHg, P=0.005) and incidence of ≥moderate prosthesis-patient mismatch (36.0% vs. 8.9%, p=0.009) were lower. These hemodynamic differences were maintained at 1-year follow-up.

Conclusions: TAVR with self-expanding valves was associated with superior hemodynamic outcomes compared with balloon-expandable valves in patients with small aortic annulus.
Files in This Item:
T202100792.pdf Download
DOI
10.4070/kcj.2020.0409
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers
Yonsei Authors
Ko, Young Guk(고영국) ORCID logo https://orcid.org/0000-0001-7748-5788
Kim, Byeong Keuk(김병극) ORCID logo https://orcid.org/0000-0003-2493-066X
Kim, Jung Sun(김중선) ORCID logo https://orcid.org/0000-0003-2263-3274
Shim, Chi Young(심지영) ORCID logo https://orcid.org/0000-0002-6136-0136
Ahn, Chul-Min(안철민) ORCID logo https://orcid.org/0000-0002-7071-4370
Lee, Seung-Jun(이승준) ORCID logo https://orcid.org/0000-0002-9201-4818
Lee, Yong Joon(이용준)
Jang, Yang Soo(장양수) ORCID logo https://orcid.org/0000-0002-2169-3112
Choi, Dong Hoon(최동훈) ORCID logo https://orcid.org/0000-0002-2009-9760
Hong, Geu Ru(홍그루) ORCID logo https://orcid.org/0000-0003-4981-3304
Hong, Myeong Ki(홍명기) ORCID logo https://orcid.org/0000-0002-2090-2031
Hong, Sung Jin(홍성진) ORCID logo https://orcid.org/0000-0003-4893-039X