123 373

Cited 2 times in

Accuracy of the Hand-held Wavefront Aberrometer in Measurement of Refractive Error

DC Field Value Language
dc.contributor.author한승한-
dc.contributor.author한진우-
dc.date.accessioned2020-09-28T12:07:21Z-
dc.date.available2020-09-28T12:07:21Z-
dc.date.issued2020-06-
dc.identifier.issn1011-8942-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/179338-
dc.description.abstractPurpose: To compare refractive error measured by hand-held wavefront aberrometers with postcycloplegic autorefraction (AR) and cycloplegic refraction (CR). Methods: The medical records of patients who received refractive measurements using the wavefront aberrometer, postcycloplegic AR, and CR between January 2014 and January 2016 were retrospectively analyzed. The mean differences, 95% confidence intervals, and limits of agreement (LOA) were calculated for the refractive vector components (M, J₀, and J45 ). Results: Fifty-one patients (9.0 ± 5.5 years, male 41.2%) were enrolled in this study, and only the right eye of each was included. Refractive errors ranged from -9.25 to +7.25 diopters (D) for spherical equivalent (median, 0.75 D). The M component was not significantly different among the three methods (p = 0.080). However, the J₀ vector component was significantly different (p < 0.001). After post hoc analysis, the wavefront aberrometer obtained more positive values for J₀ compared to the other methods. The J45 component was not significantly different among the three methods (p = 0.143). The mean difference between the wavefront aberrometer and postcycloplegic AR was -0.115 D (LOA, -1.578 to 1.348 D) for M, 0.239 D (LOA, -0.371 to 0.850 D) for J₀, and -0.015 D (LOA, -0.768 to 0.738 D) for J45 . The mean difference between the wavefront aberrometer and CR was -0.220 D (LOA, -1.790 to 1.350 D) for M, 0.300 D (LOA, -0.526 to 1.127 D) for J₀, and -0.079 D (-0.662 to 0.504 D) for J45 . Conclusions: The wavefront aberrometer showed good agreement with postcycloplegic AR and CR in spherical equivalents, but tended to produce slightly myopic results. The wavefront aberrometer also overestimated with-the-rule astigmatism. Therefore, we recommend that the device be used for estimations of refractive error, which may be useful for patients who have postural difficulties, live in undeveloped countries, or are bedridden.-
dc.description.statementOfResponsibilityopen-
dc.languageEnglish-
dc.publisherKJO-
dc.relation.isPartOfKorean Journal of Ophthalmology-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.titleAccuracy of the Hand-held Wavefront Aberrometer in Measurement of Refractive Error-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Ophthalmology (안과학교실)-
dc.contributor.googleauthorJae Yong Han-
dc.contributor.googleauthorSangchul Yoon-
dc.contributor.googleauthorNicolas Scott Brown-
dc.contributor.googleauthorSueng Han Han-
dc.contributor.googleauthorJinu Han-
dc.identifier.doi10.3341/kjo.2019.0132-
dc.contributor.localIdA04303-
dc.contributor.localIdA04329-
dc.relation.journalcodeJ02931-
dc.identifier.eissn2092-9382-
dc.identifier.pmid32495531-
dc.subject.keywordCorneal wavefront aberration-
dc.subject.keywordMydriatics-
dc.subject.keywordRefractive errors-
dc.subject.keywordRefractometry-
dc.contributor.alternativeNameHan, Seung Han-
dc.contributor.affiliatedAuthor한승한-
dc.contributor.affiliatedAuthor한진우-
dc.citation.volume34-
dc.citation.number3-
dc.citation.startPage227-
dc.citation.endPage234-
dc.identifier.bibliographicCitationKorean Journal of Ophthalmology, Vol.34(3) : 227-234, 2020-06-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Ophthalmology (안과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.