273 379

Cited 0 times in

혈관내초음파로 평가한 스텐트를 삽입한 관동맥의 형태학적 특징

DC Field Value Language
dc.contributor.author이문형-
dc.contributor.author임세중-
dc.contributor.author장양수-
dc.contributor.author정남식-
dc.contributor.author홍범기-
dc.date.accessioned2020-07-03T18:07:21Z-
dc.date.available2020-07-03T18:07:21Z-
dc.date.issued1997-
dc.identifier.issn1738-5520-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/178001-
dc.description.abstractBackground Intravascular ultrasound(IVUS) provides high resolution cross-sectional images of the vessels and permits the quantiative and qualitative assessment of coronary artery disease. Stent is a figid endovascular lattice that effectively prevents elastic recoil at treated sites, but in-stent restenois is a major limitation. The purpose of thecurrent study is to assess the contribution of neointimal hyperplasia for in-stent restenosis and the distribution and morphological characteristics of neointimal hyperplasia in deployed stents. Methods Thirty patients(male 25 & female 5;31 leions) deployed with intracoronary stents underwent intravascular ultrasound imaging at follow-up at least 4 months after stenting ([mean±SD] 8.3±2.9 months). Results 1) In-stent restenosis occurred in 15 lesions out of 31 lesions at follow-up coronary angiography. There was no difference in clinical characteristics between the restenotic and the non-restenotic groups. 2) There was no difference in angiographic profiles between two groups. Deployed stents were as follows ; 16 Palmaz-Schatz(P-S) stents, 12 Gianturco-Roubin(G-R) stents, 2 Cordis stents, and 1 Microstent II. Average diameter of stents in the restenotic and the non-restenotic groups were 3.07±0.26mm and 3.16±0.30mm, respectively(p=0.38). 3) There was no difference of stent cross-sectional areas(CSA) between the non-restenotic and the restenotic groups(p=0.476), but luminal CSA of the restenotic group was significantly smaller than that of the non-restenotic group(p=0.006). 4) In the restenotic group, there were no differences of the maximal and the minimal diameters of stents, and the mean CSAs of stents among proximal, mid, and distal segments. But the mean CSA of neointimal hyperplasia at the mid segment was larger than that at the distal segment(p<0.05). There was a tendency that the mean CSA of neointimal hyperplasia at the mid segment was larger than that at the proximal segment(p=0.187). These findings were the same in the non-restenotic group. 5) In the restenotic group deployed with P-S stents, there were no differences of the maximal and the minimal diameters of stents, and the mean cross-sectional areas(CSA) of stents between each segment. But, the mean CSA of neointimal hyperplasia at the mid segment was larger than that at the distal segment(p<0.05) and there was a tendency that the mean CSA of neointimal hyperplasia at the mid segment was larger than that at the proximal segment(p=0.354). 6) In the morphology of neointimal hyperplasia of the restenotic group, eccentric form(77%) was more common than concentric form(22%). Neointimal hyperplasia occurred in focal or diffuse patterns(7 versus 8 cases). Conclusions In-stent restenosis resulted from neointimal hyperplasia which almost mainly occurred eccentrically at the mid segment of stents and in focal or diffuse patterns. Intravascular ultrasound imaging was a useful method for recognition of distribution and morphological characteristics of neointimal hyperplasia at follow-up of deployed stents.-
dc.description.statementOfResponsibilityopen-
dc.languageKorean-
dc.publisher대한심장학회-
dc.relation.isPartOfKorean Circulation Journal (순환기)-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.title혈관내초음파로 평가한 스텐트를 삽입한 관동맥의 형태학적 특징-
dc.title.alternativeMorphological Characteristics of Intimal Hyperplasia in Stented Coronary Arteries Assessed with Intravascular Ultrasound-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Internal Medicine (내과학교실)-
dc.contributor.googleauthor정남식-
dc.contributor.googleauthor홍범기-
dc.contributor.googleauthor임세중-
dc.contributor.googleauthor백성일-
dc.contributor.googleauthor이문형-
dc.contributor.googleauthor장양수-
dc.contributor.googleauthor심원흠-
dc.contributor.googleauthor조승연-
dc.contributor.googleauthor김성순-
dc.identifier.doi10.4070/kcj.1997.27.8.851-
dc.contributor.localIdA02766-
dc.contributor.localIdA03372-
dc.contributor.localIdA03448-
dc.contributor.localIdA03585-
dc.contributor.localIdA04394-
dc.relation.journalcodeJ01953-
dc.identifier.eissn1738-5555-
dc.subject.keywordintranacular ultrasound-
dc.subject.keywordstent restenosis-
dc.subject.keywordenointimal hyperplasia-
dc.contributor.alternativeNameLee, Moon-Hyoung-
dc.contributor.affiliatedAuthor이문형-
dc.contributor.affiliatedAuthor임세중-
dc.contributor.affiliatedAuthor장양수-
dc.contributor.affiliatedAuthor정남식-
dc.contributor.affiliatedAuthor홍범기-
dc.citation.volume27-
dc.citation.number8-
dc.citation.startPage851-
dc.citation.endPage861-
dc.identifier.bibliographicCitationKorean Circulation Journal (순환기), Vol.27(8) : 851-861, 1997-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.