302 534

Cited 8 times in

Inter- and Intra-Observer Variability of the Volume of Cervical Ossification of the Posterior Longitudinal Ligament Using Medical Image Processing Software

Authors
 Dong Ah Shin  ;  Gyu Yeul Ji  ;  Chang Hyun Oh  ;  Keung Nyun Kim  ;  Do Heum Yoon  ;  Hyunchul Shin 
Citation
 JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, Vol.60(4) : 441-447, 2017 
Journal Title
JOURNAL OF KOREAN NEUROSURGICAL SOCIETY
ISSN
 2005-3711 
Issue Date
2017
Keywords
3D analysis ; MIMICS ; Ossification ; Posterior longitudinal ligament ; Volume
Abstract
OBJECTIVE: Computed tomography (CT)-based method of three dimensional (3D) analysis (MIMICS®, Materialise, Leuven, Belgium) is reported as very useful software for evaluation of OPLL, but its reliability and reproducibility are obscure. This study was conducted to evaluate the accuracy of MIMICS® system, and inter- and intra-observer reliability in the measurement of OPLL.

METHODS: Three neurosurgeons independently analyzed the randomly selected 10 OPLL cases with medical image processing software (MIMICS®) which create 3D model with Digital Imaging and Communication in Medicine (DICOM) data from CT images after brief explanation was given to examiners before the image construction steps. To assess the reliability of inter- and intra-examiner intraclass correlation coefficient (ICC), 3 examiners measured 4 parameters (volume, length, width, and length) in 10 cases 2 times with 1-week interval.

RESULTS: The inter-examiner ICCs among 3 examiners were 0.996 (95% confidence interval [CI], 0.987-0.999) for volume measurement, 0.973 (95% CI, 0.907-0.978) for thickness, 0.969 (95% CI, 0.895-0.993) for width, and 0.995 (95% CI, 0.983-0.999) for length. The intra-examiner ICCs were 0.994 (range, 0.991-0.996) for volume, 0.996 (range, 0.944-0.998) for length, 0.930 (range, 0.873-0.947) for width, and 0.987 (range, 0.985-0.995) for length.

CONCLUSION: The medical image processing software (MIMICS®) provided detailed quantification OPLL volume with minimal error of inter- and intra-observer reliability in the measurement of OPLL.
Files in This Item:
T201705524.pdf Download
DOI
10.3340/jkns.2015.0708.014
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Neurosurgery (신경외과학교실) > 1. Journal Papers
Yonsei Authors
Kim, Keung Nyun(김긍년)
Shin, Dong Ah(신동아) ORCID logo https://orcid.org/0000-0002-5225-4083
Yoon, Do Heum(윤도흠) ORCID logo https://orcid.org/0000-0003-1452-5724
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/161676
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links