303 429

Cited 0 times in

Effective thermal destruction of residual tubal epithelium using an advanced sealing device in opportunistic salpingectomy: A randomized trial

Authors
 Hyun-Jin Choi  ;  Hyun-Soo Kim  ;  Tae-Joong Kim  ;  Sang Yong Song  ;  E Sun Paik  ;  Eun Jin Heo  ;  Jin-Young Park  ;  Yoo-Young Lee  ;  Chel Hun Choi  ;  Jeong-Won Lee  ;  Byoung-Gie Kim  ;  Duk-Soo Bae 
Citation
 Gynecology and Minimally Invasive Therapy, Vol.6(3) : 108-112, 2017 
Journal Title
Gynecology and Minimally Invasive Therapy
Issue Date
2017
Abstract
Objective : To examine the effectiveness of proximal tube destruction at the uterine cornu by additional application of a sealing device.

Methods : A single-center randomized trial was conducted on 40 patients receiving a laparo-endoscopic single-site hysterectomy with opportunistic salpingectomy. We randomized patients into two groups at the time of admission to determine the laterality of additional thermal cauterization. Additional thermal cauterization for 10 seconds was applied on the right cornu in one group and on the left cornu in the other group. Three pieces of cornual tissue from each cornu were biopsied. One gynecological pathologist examined the cornual tissue to determine the residual tubal epithelium (TE) and thermal destruction of the specimens.

Results ; Of the 40 patients enrolled in this study between September 2012 and July 2014, samples of 26 patients were subjected to tissue analysis. Residual TE was found in the cornu in 73.1% (19/26) and 65.4 % (17/26) of tissues from the side of no additional cauterization (NO) and the side of additional cauterization (AD), respectively (p < 0.001). Residual TE was detected in 5.3% (1/19) and 94.1% (16/17) of the specimens from the NO and AD groups, respectively.

Conclusion : We observed that a high incidence of residual TE and efficacious cauterization-induced thermal destruction was achieved following 10 seconds of additional cauterization. These results suggest that additional cauterization of the uterine cornu using the sealing device effectively destroys residual TE after salpingectomy.
Files in This Item:
T201703056.pdf Download
DOI
10.1016/j.gmit.2016.12.005
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Pathology (병리학교실) > 1. Journal Papers
Yonsei Authors
Kim, Hyun-Soo(김현수)
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/160690
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links