0 518

Cited 22 times in

Comparison of Visual Assessment of Breast Density in BI-RADS 4th and 5th Editions With Automated Volumetric Measurement

Authors
 Ji Hyun Youk  ;  So Jung Kim  ;  Eun Ju Son  ;  Hye Mi Gweon  ;  Jeong-Ah Kim 
Citation
 AMERICAN JOURNAL OF ROENTGENOLOGY, Vol.209(3) : 703-708, 2017 
Journal Title
AMERICAN JOURNAL OF ROENTGENOLOGY
ISSN
 0361-803X 
Issue Date
2017
MeSH
Adult ; Aged ; Breast Density* ; Breast Neoplasms/diagnostic imaging* ; Breast Neoplasms/pathology ; Female ; Humans ; Mammography ; Middle Aged ; Radiographic Image Interpretation, Computer-Assisted ; Reproducibility of Results ; Retrospective Studies ; Software
Keywords
BI-RADS ; breast density ; breast imaging ; computer-assisted interpretation ; mammography
Abstract
OBJECTIVE: The purpose of this study was to compare visual assessments of mammographic breast density by radiologists using BI-RADS 4th and 5th editions in correlation with automated volumetric breast density measurements.

MATERIALS AND METHODS: A total of 337 consecutive full-field digital mammographic examinations with standard views were retrospectively assessed by two radiologists for mammographic breast density according to BI-RADS 4th and 5th editions. Fully automated measurement of the volume of fibroglandular tissue and total breast and percentage breast density was performed with a commercially available software program. Interobserver and intraobserver agreement was assessed with kappa statistics. The distributions of breast density categories for both editions of BI-RADS were compared and correlated with volumetric data.

RESULTS: Interobserver agreement on breast density category was moderate to substantial (κ = 0.58-0.63) with use of BI-RADS 4th edition and substantial (κ = 0.63-0.66) with use of the 5th edition but without significant difference between the two editions. For intraobserver agreement between the two editions, the distributions of density category were significantly different (p < 0.0001), the proportions of dense breast increased, and the proportion of fatty breast decreased with use of the 5th edition compared with the 4th edition (p < 0.0001). All volumetric breast density data, including percentage breast density, were significantly different among density categories (p < 0.0001) and had significant correlation with visual assessment for both editions of BI-RADS (p < 0.01).

CONCLUSION: Assessment using BI-RADS 5th edition revealed a higher proportion of dense breast than assessment using BI-RADS 4th edition. Nevertheless, automated volumetric density assessment had good correlation with visual assessment for both editions of BI-RADS.
Full Text
https://www.ajronline.org/doi/abs/10.2214/AJR.16.17525
DOI
10.2214/AJR.16.17525
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers
Yonsei Authors
Gweon, Hye Mi(권혜미) ORCID logo https://orcid.org/0000-0002-3054-1532
Kim, So Jung(김소중)
Kim, Jeong Ah(김정아) ORCID logo https://orcid.org/0000-0003-4949-4913
Son, Eun Ju(손은주) ORCID logo https://orcid.org/0000-0002-7895-0335
Youk, Ji Hyun(육지현) ORCID logo https://orcid.org/0000-0002-7787-780X
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/160671
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links