199 504

Cited 8 times in

Predicting Peri-Device Leakage of Left Atrial Appendage Device Closure Using Novel Three-Dimensional Geometric CT Analysis

DC Field Value Language
dc.contributor.author김중선-
dc.contributor.author심지영-
dc.contributor.author장양수-
dc.contributor.author장혁재-
dc.contributor.author정남식-
dc.contributor.author정혜문-
dc.contributor.author조인정-
dc.contributor.author홍그루-
dc.date.accessioned2018-03-26T17:05:43Z-
dc.date.available2018-03-26T17:05:43Z-
dc.date.issued2015-
dc.identifier.issn1975-4612-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/157176-
dc.description.abstractBACKGROUND: After left atrial appendage (LAA) device closure, peri-device leakage into the LAA persists due to incomplete occlusion. We hypothesized that pre-procedural three-dimensional (3D) geometric analysis of the interatrial septum (IAS) and LAA orifice can predict this leakage. We investigated the predictive parameters of LAA device closure obtained from baseline cardiac computerized tomography (CT) using a novel 3D analysis system. METHODS: We conducted a retrospective study of 22 patients who underwent LAA device closure. We defined peri-device leakage as the presence of a Doppler signal inside the LAA after device deployment (group 2, n = 5) compared with patients without peri-device leakage (group 1, n = 17). Conventional parameters were measured by cardiac CT. Angles θ and φ were defined between the IAS plane and the line, linking the LAA orifice center and foramen ovale. RESULTS: Group 2 exhibited significantly better left atrial (LA) function than group 1 (p = 0.031). Pre-procedural θ was also larger in this group (41.9° vs. 52.3°, p = 0.019). The LAA cauliflower-type morphology was more common in group 2. Overall, the patients' LA reserve significantly decreased after the procedure (21.7 mm(3) vs. 17.8 mm(3), p = 0.035). However, we observed no significant interval changes in pre- and post-procedural values of θ and φ in either group (all p > 0.05). CONCLUSION: Angles between the IAS and LAA orifice might be a novel anatomical parameter for predicting peri-device leakage after LAA device closure. In addition, 3D CT analysis of the LA and LAA orifice could be used to identify clinically favorable candidates for LAA device closure.-
dc.description.statementOfResponsibilityopen-
dc.languageKorean, English-
dc.publisherKorean Society of Echocardiography-
dc.relation.isPartOfJournal of Cardiovascular Ultrasound-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rightshttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.titlePredicting Peri-Device Leakage of Left Atrial Appendage Device Closure Using Novel Three-Dimensional Geometric CT Analysis-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine-
dc.contributor.departmentDept. of Internal Medicine-
dc.contributor.googleauthorHyemoon Chung-
dc.contributor.googleauthorByunghwan Jeon-
dc.contributor.googleauthorHyuk-Jae Chang-
dc.contributor.googleauthorDongjin Han-
dc.contributor.googleauthorHackjoon Shim-
dc.contributor.googleauthorIn Jeong Cho-
dc.contributor.googleauthorChi Young Shim-
dc.contributor.googleauthorGeu-Ru Hong-
dc.contributor.googleauthorJung-Sun Kim-
dc.contributor.googleauthorYangsoo Jang-
dc.contributor.googleauthorNamsik Chung-
dc.identifier.doi10.4250/jcu.2015.23.4.211-
dc.contributor.localIdA00961-
dc.contributor.localIdA02213-
dc.contributor.localIdA03448-
dc.contributor.localIdA03490-
dc.contributor.localIdA03585-
dc.contributor.localIdA03779-
dc.contributor.localIdA03892-
dc.contributor.localIdA04386-
dc.relation.journalcodeJ01298-
dc.identifier.eissn2005-9655-
dc.identifier.pmid26755929-
dc.subject.keywordCardiac CT-
dc.subject.keywordLeft atrial appendage-
dc.subject.keywordOcclusion-
dc.subject.keywordPeri-device leakage-
dc.contributor.alternativeNameKim, Jung Sun-
dc.contributor.alternativeNameShim, Chi Young-
dc.contributor.alternativeNameJang, Yang Soo-
dc.contributor.alternativeNameChang, Hyuck Jae-
dc.contributor.alternativeNameChung, Nam Sik-
dc.contributor.alternativeNameChung, Hye Moon-
dc.contributor.alternativeNameCho, In Jeong-
dc.contributor.alternativeNameHong, Geu Ru-
dc.contributor.affiliatedAuthorKim, Jung Sun-
dc.contributor.affiliatedAuthorShim, Chi Young-
dc.contributor.affiliatedAuthorJang, Yang Soo-
dc.contributor.affiliatedAuthorChang, Hyuck Jae-
dc.contributor.affiliatedAuthorChung, Nam Sik-
dc.contributor.affiliatedAuthorChung, Hye Moon-
dc.contributor.affiliatedAuthorCho, In Jeong-
dc.contributor.affiliatedAuthorHong, Geu Ru-
dc.citation.volume23-
dc.citation.number4-
dc.citation.startPage211-
dc.citation.endPage218-
dc.identifier.bibliographicCitationJournal of Cardiovascular Ultrasound, Vol.23(4) : 211-218, 2015-
dc.identifier.rimsid41737-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.