Comparison of Inter-Observer Variability and Diagnostic Performance of the Fifth Edition of BI-RADS for Breast Ultrasound of Static versus Video Images

DC Field Value Language
dc.contributor.author김민정-
dc.contributor.author육지현-
dc.contributor.author윤정현-
dc.contributor.author정인경-
dc.date.accessioned2017-10-26T07:15:20Z-
dc.date.available2017-10-26T07:15:20Z-
dc.date.issued2016-
dc.identifier.issn0301-5629-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/151803-
dc.description.abstractOur aim was to compare the inter-observer variability and diagnostic performance of the Breast Imaging Reporting and Data System (BI-RADS) lexicon for breast ultrasound of static and video images. Ninety-nine breast masses visible on ultrasound examination from 95 women 19-81 y of age at five institutions were enrolled in this study. They were scheduled to undergo biopsy or surgery or had been stable for at least 2 y of ultrasound follow-up after benign biopsy results or typically benign findings. For each mass, representative long- and short-axis static ultrasound images were acquired; real-time long- and short-axis B-mode video images through the mass area were separately saved as cine clips. Each image was reviewed independently by five radiologists who were asked to classify ultrasound features according to the fifth edition of the BI-RADS lexicon. Inter-observer variability was assessed using kappa (κ) statistics. Diagnostic performance on static and video images was compared using the area under the receiver operating characteristic curve. No significant difference was found in κ values between static and video images for all descriptors, although κ values of video images were higher than those of static images for shape, orientation, margin and calcifications. After receiver operating characteristic curve analysis, the video images (0.83, range: 0.77-0.87) had higher areas under the curve than the static images (0.80, range: 0.75-0.83; p = 0.08). Inter-observer variability and diagnostic performance of video images was similar to that of static images on breast ultrasonography according to the new edition of BI-RADS.-
dc.description.statementOfResponsibilityrestriction-
dc.languageEnglish-
dc.publisherPergamon Press-
dc.relation.isPartOfULTRASOUND IN MEDICINE AND BIOLOGY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAdult-
dc.subject.MESHAged-
dc.subject.MESHAged, 80 and over-
dc.subject.MESHBreast/diagnostic imaging-
dc.subject.MESHBreast Neoplasms/diagnostic imaging*-
dc.subject.MESHFemale-
dc.subject.MESHHumans-
dc.subject.MESHMiddle Aged-
dc.subject.MESHObserver Variation-
dc.subject.MESHROC Curve-
dc.subject.MESHRadiology Information Systems*-
dc.subject.MESHReproducibility of Results-
dc.subject.MESHUltrasonography, Mammary/methods*-
dc.subject.MESHVideotape Recording-
dc.subject.MESHYoung Adult-
dc.titleComparison of Inter-Observer Variability and Diagnostic Performance of the Fifth Edition of BI-RADS for Breast Ultrasound of Static versus Video Images-
dc.typeArticle-
dc.publisher.locationEngland-
dc.contributor.collegeCollege of Medicine-
dc.contributor.departmentDept. of Radiology-
dc.contributor.googleauthorJi Hyun Youk-
dc.contributor.googleauthorInkyung Jung-
dc.contributor.googleauthorJung Hyun Yoon-
dc.contributor.googleauthorSung Hun Kim-
dc.contributor.googleauthorYou Me Kim-
dc.contributor.googleauthorEun Hye Lee-
dc.contributor.googleauthorSun Hye Jeong-
dc.contributor.googleauthorMin Jung Kim-
dc.identifier.doi10.1016/j.ultrasmedbio.2016.05.006-
dc.contributor.localIdA02537-
dc.contributor.localIdA02595-
dc.contributor.localIdA03693-
dc.contributor.localIdA00473-
dc.relation.journalcodeJ02769-
dc.identifier.eissn1879-291X-
dc.identifier.pmid27324292-
dc.identifier.urlhttp://www.sciencedirect.com/science/article/pii/S0301562916300631-
dc.subject.keywordBI-RADS-
dc.subject.keywordBreast diseases-
dc.subject.keywordBreast neoplasms-
dc.subject.keywordObserver variation-
dc.subject.keywordUltrasonography-
dc.contributor.alternativeNameKim, Min Jung-
dc.contributor.alternativeNameYouk, Ji Hyun-
dc.contributor.alternativeNameYoon, Jung Hyun-
dc.contributor.alternativeNameJung, In Kyung-
dc.contributor.affiliatedAuthorYouk, Ji Hyun-
dc.contributor.affiliatedAuthorYoon, Jung Hyun-
dc.contributor.affiliatedAuthorJung, In Kyung-
dc.contributor.affiliatedAuthorKim, Min Jung-
dc.citation.volume42-
dc.citation.number9-
dc.citation.startPage2083-
dc.citation.endPage2088-
dc.identifier.bibliographicCitationULTRASOUND IN MEDICINE AND BIOLOGY, Vol.42(9) : 2083-2088, 2016-
dc.date.modified2017-10-24-
dc.identifier.rimsid45813-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Biomedical Systems Informatics (의생명시스템정보학교실) > 1. Journal Papers
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.