0 815

Cited 6 times in

Evaluation of a Rapid Immunochromatographic Treponemal Antibody Test Comparing the Treponema Pallidum Particle Agglutination Assay

Authors
 Jong-Han Lee  ;  Chae Seung Lim  ;  Hyon-Suk Kim  ;  Min-Geol Lee 
Citation
 JOURNAL OF CLINICAL LABORATORY ANALYSIS, Vol.29(5) : 383-386, 2015 
Journal Title
JOURNAL OF CLINICAL LABORATORY ANALYSIS
ISSN
 0887-8013 
Issue Date
2015
MeSH
Antibodies, Bacterial/blood* ; Case-Control Studies ; Humans ; Immunochromatography/methods* ; Limit of Detection ; Male ; Middle Aged ; Reproducibility of Results ; Syphilis/diagnosis* ; Syphilis Serodiagnosis/methods* ; Treponema pallidum/immunology ; Treponema pallidum/isolation & purification*
Keywords
Syphilis ; Treponema pallidum particle agglutination (TPPA) ; agreement ; rapid immunochromatographic test
Abstract
BACKGROUND: In addition to conventional tests, several methods for detection of treponema-specific antibodies in clinical settings have been recently introduced. We aim to comparatively evaluate a rapid immunochromatographic test (ICT) for Treponema pallidum specific antibody (SD Bioline Syphilis 3.0) and the T. pallidum particle agglutination (TPPA) assay.

METHODS: In all, 132 serum samples from 78 syphilis patients and 54 syphilis-negative controls were analyzed. SD Bioline Syphilis 3.0 test (Standard Diagnostic, Inc., Yongin, Korea) was evaluated and compared to Serodia TPPA assay (Fujirebio, Inc., Tokyo, Japan). All discrepant results between the two assays were repeatedly tested and evaluated by the fluorescent treponemal antibody-absorption (FTA-ABS) assay. Test reproducibility and 95% limit of detection of SD Bioline Syphilis 3.0 were determined across three different lots for seven consecutive days in triplicate. Interference due to autoantibodies and pregnancy was also tested.

RESULTS: Percent agreement between SD Bioline Syphilis 3.0 and TPPA assays was 99.2%. Sensitivity and specificity were 100%, respectively. In TPPA assay, test-to-test, day-to-day, and lot-to-lot variations were not identified until 1:320 titer (eightfold dilutions). There was no interference due to the presence of antinuclear antibodies or samples or pregnancy.

CONCLUSIONS: Percent agreement of SD Syphilis 3.0 and TPPA was very good. Sensitivity and specificity were appropriate for T. pallidum antibody detection. Thus, a rapid ICT could be suitable for syphilis antibody detection.
Full Text
http://onlinelibrary.wiley.com/doi/10.1002/jcla.21783/abstract
DOI
10.1002/jcla.21783
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Dermatology (피부과학교실) > 1. Journal Papers
1. College of Medicine (의과대학) > Dept. of Laboratory Medicine (진단검사의학교실) > 1. Journal Papers
Yonsei Authors
Kim, Hyon Suk(김현숙) ORCID logo https://orcid.org/0000-0001-5662-7740
Lee, Min Geol(이민걸) ORCID logo https://orcid.org/0000-0001-7040-5335
Lee, Jong Han(이종한)
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/141829
사서에게 알리기