508 958

Cited 7 times in

Permeability Parameters Measured with Dynamic Contrast-Enhanced MRI: Correlation with the Extravasation of Evans Blue in a Rat Model of Transient Cerebral Ischemia

Authors
 Hyun Seok Choi  ;  Sung Soo Ahn  ;  Na Young Shin  ;  Jinna Kim  ;  Jae Hyung Kim  ;  Jong Eun Lee  ;  Hye Yeon Lee  ;  Ji Hoe Heo  ;  Seung Koo Lee 
Citation
 KOREAN JOURNAL OF RADIOLOGY, Vol.16(4) : 791-797, 2015 
Journal Title
KOREAN JOURNAL OF RADIOLOGY
ISSN
 1229-6929 
Issue Date
2015
MeSH
Animals ; Blood-Brain Barrier/pathology ; Capillary Permeability ; Contrast Media ; Disease Models, Animal ; Evans Blue/analysis ; Ischemic Attack, Transient/diagnosis* ; Magnetic Resonance Imaging/instrumentation ; Magnetic Resonance Imaging/methods* ; Male ; Rats ; Rats, Sprague-Dawley ; Stroke/diagnosis
Keywords
Animal models ; Blood-brain barrier ; Brain ischemia ; Dynamic contrast-enhanced MRI ; Kinetic modeling
Abstract
OBJECTIVE: The purpose of this study was to correlate permeability parameters measured with dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) using a clinical 3-tesla scanner with extravasation of Evans blue in a rat model with transient cerebral ischemia.
MATERIALS AND METHODS: Sprague-Dawley rats (n = 13) with transient middle cerebral artery occlusion were imaged using a 3-tesla MRI with an 8-channel wrist coil. DCE-MRI was performed 12 hours, 18 hours, and 36 hours after reperfusion. Permeability parameters (K(trans), ve, and vp) from DCE-MRI were calculated. Evans blue was injected after DCE-MRI and extravasation of Evans blue was correlated as a reference with the integrity of the blood-brain barrier. Correlation analysis was performed between permeability parameters and the extravasation of Evans blue.
RESULTS: All permeability parameters (K(trans), ve, and vp) showed a linear correlation with extravasation of Evans blue. Among them, K(trans) showed highest values of both the correlation coefficient and the coefficient of determination (0.687 and 0.473 respectively, p < 0.001).
CONCLUSION: Permeability parameters obtained by DCE-MRI at 3-T are well-correlated with Evans blue extravasation, and K(trans) shows the strongest correlation among the tested parameters.
Files in This Item:
T201503587.pdf Download
DOI
10.3348/kjr.2015.16.4.791
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Anatomy (해부학교실) > 1. Journal Papers
1. College of Medicine (의과대학) > Dept. of Neurology (신경과학교실) > 1. Journal Papers
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers
Yonsei Authors
Kim, Jinna(김진아) ORCID logo https://orcid.org/0000-0002-9978-4356
Shin, Na Young(신나영)
Ahn, Sung Soo(안성수) ORCID logo https://orcid.org/0000-0002-0503-5558
Lee, Seung Koo(이승구) ORCID logo https://orcid.org/0000-0001-5646-4072
Lee, Jong Eun(이종은) ORCID logo https://orcid.org/0000-0001-6203-7413
Lee, Hye Yeon(이혜연) ORCID logo https://orcid.org/0000-0001-6945-1967
Heo, Ji Hoe(허지회) ORCID logo https://orcid.org/0000-0001-9898-3321
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/141177
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links