0 727

Cited 12 times in

Eccentric morphology of jailed side-branch ostium after stent crossover in coronary bifurcation lesions: a three-dimensional optical coherence tomographic analysis

DC Field Value Language
dc.contributor.author최동훈-
dc.contributor.author홍명기-
dc.contributor.author고영국-
dc.contributor.author김병극-
dc.contributor.author김중선-
dc.contributor.author신동호-
dc.contributor.author양필성-
dc.contributor.author장양수-
dc.date.accessioned2016-02-04T11:12:55Z-
dc.date.available2016-02-04T11:12:55Z-
dc.date.issued2015-
dc.identifier.issn0914-5087-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/139922-
dc.description.abstractBACKGROUND: Angiographic stenosis of a jailed side-branch ostium is usually observed after a single-stent crossover at coronary bifurcation lesions. However, the stenosis severity is typically overestimated due to the limited information obtained from two-dimensional morphology by angiography. We evaluated the actual stenosis of jailed side-branch ostium using three-dimensional (3D) optical coherence tomography (OCT). METHODS: Using 3D reconstructions of OCT data, we analyzed minimal lumen area (MLA) and eccentricity of the jailed side-branch ostium in 41 patients who were treated with single stent crossover at coronary bifurcation lesions and subsequently underwent serial OCT follow-up. RESULTS: The MLA of jailed side-branch ostium calculated from quantitative coronary angiography (QCA) assuming a circular lumen markedly decreased after stent implantation (1.73±1.22mm(2) pre-intervention to 0.84±0.91mm(2) post-intervention, p<0.001). However, the MLA of jailed side-branch ostium measured at post-intervention by 3D-OCT (2.67±1.75mm(2)) was significantly larger than that measured by QCA (p<0.001). There were no statistically significant changes in MLA of jailed side-branch ostium based on 3D-OCT measurements during the follow-up (2.35±1.50mm(2) at 3-6 months post-intervention; 2.44±1.27mm(2) at 1-2 years post-intervention, p=0.098). The shapes of the jailed side-branch ostium were nearly elliptical (mean eccentricity index: 2.97±1.27 post-intervention; 2.79±1.17 at 3-6 months post-intervention; 2.59±1.02 at 1-2 years post-intervention). CONCLUSIONS: Compared to 3D-OCT measurements, QCA measurements overestimated the jailed side-branch ostial stenosis after single stent crossover due to eccentric morphology from orthogonal projection in coronary angiography. Significant changes in the MLA of jailed side-branch ostium by 3D-OCT were not observed during the follow-up.-
dc.description.statementOfResponsibilityopen-
dc.format.extent305~310-
dc.relation.isPartOfJOURNAL OF CARDIOLOGY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAged-
dc.subject.MESHCoronary Angiography-
dc.subject.MESHCoronary Stenosis/diagnosis*-
dc.subject.MESHCoronary Stenosis/surgery-
dc.subject.MESHCoronary Vessels/pathology*-
dc.subject.MESHFemale-
dc.subject.MESHHumans-
dc.subject.MESHImaging, Three-Dimensional/methods*-
dc.subject.MESHMale-
dc.subject.MESHMiddle Aged-
dc.subject.MESHStents-
dc.subject.MESHTomography, Optical Coherence/methods*-
dc.titleEccentric morphology of jailed side-branch ostium after stent crossover in coronary bifurcation lesions: a three-dimensional optical coherence tomographic analysis-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Internal Medicine (내과학)-
dc.contributor.googleauthorPil-Sung Yang-
dc.contributor.googleauthorJinyong Ha,-
dc.contributor.googleauthorJung-Sun Kim-
dc.contributor.googleauthorSeungsu Park-
dc.contributor.googleauthorJinju Bae-
dc.contributor.googleauthorDong-Ho Shin-
dc.contributor.googleauthorByeong-Keuk Kim-
dc.contributor.googleauthorYoung-Guk Ko-
dc.contributor.googleauthorDonghoon Choi-
dc.contributor.googleauthorYangsoo Jang-
dc.contributor.googleauthorMyeong-Ki Hong-
dc.identifier.doi10.1016/j.jjcc.2014.12.004-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA04053-
dc.contributor.localIdA04391-
dc.contributor.localIdA00127-
dc.contributor.localIdA00493-
dc.contributor.localIdA00961-
dc.contributor.localIdA02097-
dc.contributor.localIdA02323-
dc.contributor.localIdA03448-
dc.relation.journalcodeJ01287-
dc.identifier.eissn1876-4738-
dc.identifier.pmid25601268-
dc.identifier.urlhttp://www.sciencedirect.com/science/article/pii/S0914508714003566-
dc.subject.keywordBifurcation-
dc.subject.keywordOptical coherence tomography-
dc.subject.keywordStent-
dc.contributor.alternativeNameChoi, Dong Hoon-
dc.contributor.alternativeNameHong, Myeong Ki-
dc.contributor.alternativeNameKo, Young Guk-
dc.contributor.alternativeNameKim, Byeong Keuk-
dc.contributor.alternativeNameKim, Jung Sun-
dc.contributor.alternativeNameShin, Dong Ho-
dc.contributor.alternativeNameYang, Pil Sung-
dc.contributor.alternativeNameJang, Yang Soo-
dc.contributor.affiliatedAuthorChoi, Dong Hoon-
dc.contributor.affiliatedAuthorHong, Myeong Ki-
dc.contributor.affiliatedAuthorKo, Young Guk-
dc.contributor.affiliatedAuthorKim, Byeong Keuk-
dc.contributor.affiliatedAuthorKim, Jung Sun-
dc.contributor.affiliatedAuthorShin, Dong Ho-
dc.contributor.affiliatedAuthorYang, Pil Sung-
dc.contributor.affiliatedAuthorJang, Yang Soo-
dc.rights.accessRightsnot free-
dc.citation.volume65-
dc.citation.number4-
dc.citation.startPage305-
dc.citation.endPage310-
dc.identifier.bibliographicCitationJOURNAL OF CARDIOLOGY, Vol.65(4) : 305-310, 2015-
dc.identifier.rimsid48381-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.