203 537

Cited 0 times in

임프란트 미세나사선이 주위골 수준변화에 미치는 영향에 대한 1년간의 전향적 비교 연구

Other Titles
 An 1year prospective comparative study evaluateing the effect of microthread on the maintenance of marginal bone level 
Authors
 신동환  ;  조규성  ;  문익상  ;  박광호 
Citation
 Journal of Korean Academy of Periodontology (대한치주과학회지), Vol.33(3) : 349-358, 2003 
Journal Title
Journal of Korean Academy of Periodontology(대한치주과학회지)
ISSN
 0250-3352 
Issue Date
2003
MeSH
astra tech implant ; microthread ; marginal bone level ; radiographic evaluation
Keywords
astra tech implant ; microthread ; marginal bone level ; radiographic evaluation
Abstract
The success of dental implant therapy relies mainly upon the presence and maintenance of bone adjacent to implant. An 1-year prospective study was performed, upon the patients who were diagnosed as having chronic adult periodontitis, and had been treated with dental implant. The purpose of this study was to measure the radiographic bone level changes proximal to Astra Tech Single Tooth Implants (ATST, Astra Tech AB, Mölndal, Sweden) with microthread and Astra Tech TiOblast Implant (ATTB) without microthread supporting fixed partial prosthesis. Measurements were used to determine mean marginal bone loss during the first year of loading, 17 subjects with its partial prosthesis supported by 37 implants were followed up for an 1-year period. The marginal bone loss of implants was positively correlated with the retention factor, microthread(Microthread™) in crestal area of ATST. The results were as follows. 1. The mean marginal bone loss of ATST was 0.226±0.395mm, while ATTB was 0.440±0.360mm. There was a statistically significant difference between ATST and ATTB (p<0.05). 2. The mean bone loss of the upper jaw fixtures was 0.269±0.265mm for ATST and 0.529±0.417mm for ATTB . There was a statistically significant difference between ATST and ATTB (p<0.05). In the lower jaw the corresponding figures were 0.167±0.231mm and 0.313±0.214mm, respectively. There was no significant difference between ATST and ATTB (p>0.05). 3. The mean bone loss of ATST was lower than that of ATTB at all sites according to bone quality. There was a statistically significant difference between ATST and ATTB at bone quality type III(p <0.05). In conclusion, the mean bone loss of ATST was smaller than that of ATTB . Therefore, the retention factor of crestal area, microthread (Microthread™) was effective to maintenance of marginal bone level around fixture.
Files in This Item:
T200306798.pdf Download
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Periodontics (치주과학교실) > 1. Journal Papers
Yonsei Authors
Moon, Ik Sang(문익상)
Cho, Kyoo Sung(조규성) ORCID logo https://orcid.org/0000-0002-6777-5287
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/114479
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links