dc.description.abstractBACKGROUND AND OBJECTIVES: Coronary flow reserve (CFR) decreases in the presence of significant coronary stenosis. Hence, CFR can be used for the detection of restenosis after percutaneous coronary intervention (PCI). However, because CFR can also be affected by other conditions such as endothelial dysfunction, microvascular damage, and left ventricular hypertrophy, the absolute value of CFR is not routinely used for detection of coronary restenosis. We hypothesized that changes in the value of CFR, rather than the absolute CFR value, are better correlated with restenosis in various clinical settings. SUBJECTS AND METHODS: We studied 99 patients (71 males/28 females, mean age 58+/-11 years) who underwent successful PCI of the left anterior descending artery. Pre-PCI diagnoses were as follows: 37 unstable angina, 35 stable angina, 27 acute myocardial infarction. CFR using transthoracic Doppler was measured at 48 hours after PCI and at the time of follow-up angiography (6.0+/-1.5 months later). Coronary flow velocity was measured in the distal left anterior descending artery with a 7 MHz transducer (HDI 5,000, Philips, The Netherlands) at baseline and during intravenous infusion of adenosine (140 microgram.kg(-1).min(-1)). Mean diastolic coronary flow velocities from at least three cardiac cycles were averaged. RESULTS: CFRs in 69 patients without restenosis were 2.55+/-0.99 at 48 hours after PCI and 2.93+/-1.00 at follow-up (p<0.005). CFRs in 30 patients with restenosis (>50% in diameter stenosis) decreased significantly from 2.70+/-1.01 at 48 hours after PCI to 1.98+/-0.91 at follow-up (p<0.001). There was a significant difference in CFR change (ratio of CFR(followup)/CFR(initial)) between the two groups. CFR change had a better receiver operating characteristics (ROC) curve than absolute CFR for prediction of restenosis [area under the curve (AUC) for absolute CFR=0.76, AUC for CFR change=0.82]. CONCLUSION: Restenosis after PCI leads to a significant decrease in CFR, even in the presence of variable baseline CFR values. Serial measurements of CFR can be used to detect restenosis after PCI-
dc.description.statementOfResponsibilityopen-
dc.format.extent325~330-
dc.relation.isPartOfKOREAN CIRCULATION JOURNAL-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.title경흉부 심초음파를 이용한 관동맥 혈류속도 예비력에 의한 경피적 관동맥 성형술후 재협착의 비침습적인 진단-
dc.title.alternativeDiagnosis of Coronary Restenosis Using Coronary Flow Reserve Measurements Obtained Through Transthoracic Doppler Echocardiography-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Internal Medicine (내과학)-
dc.contributor.googleauthor임세중-
dc.contributor.googleauthor고영국-
dc.contributor.googleauthor강석민-
dc.contributor.googleauthor하종원-
dc.contributor.googleauthor최동훈-
dc.contributor.googleauthor장양수-
dc.contributor.googleauthor정남식-
dc.identifier.doi10.4070/kcj.2008.38.6.325-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA00037-
dc.contributor.localIdA00127-
dc.contributor.localIdA03372-
dc.contributor.localIdA03448-
dc.contributor.localIdA03585-
dc.contributor.localIdA04053-
dc.contributor.localIdA04257-
dc.relation.journalcodeJ01952-
dc.identifier.eissn1738-5555-
dc.identifier.pmidCoronary flow reserve ; Coronary restenosis ; Echocardiography-
dc.subject.keywordCoronary flow reserve-
dc.subject.keywordCoronary restenosis-
dc.subject.keywordEchocardiography-
dc.contributor.alternativeNameKang, Seok Min-
dc.contributor.alternativeNameKo, Young Guk-
dc.contributor.alternativeNameRim, Se Joong-
dc.contributor.alternativeNameJang, Yang Soo-
dc.contributor.alternativeNameChung, Nam Sik-
dc.contributor.alternativeNameChoi, Dong Hoon-
dc.contributor.alternativeNameHa, Jong Won-
dc.contributor.affiliatedAuthorKang, Seok Min-
dc.contributor.affiliatedAuthorKo, Young Guk-
dc.contributor.affiliatedAuthorRim, Se Joong-
dc.contributor.affiliatedAuthorJang, Yang Soo-
dc.contributor.affiliatedAuthorChung, Nam Sik-
dc.contributor.affiliatedAuthorChoi, Dong Hoon-
dc.contributor.affiliatedAuthorHa, Jong Won-
dc.rights.accessRightsfree-
dc.citation.volume38-
dc.citation.number6-
dc.citation.startPage325-
dc.citation.endPage330-
dc.identifier.bibliographicCitationKOREAN CIRCULATION JOURNAL, Vol.38(6) : 325-330, 2008-
dc.identifier.rimsid54778-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.