2 440

Cited 12 times in

Carbon nanotube-based biosensor for detection of matrix metallopeptidase-9 and S-100B

DC Field Value Language
dc.contributor.author신전수-
dc.date.accessioned2015-04-24T17:25:52Z-
dc.date.available2015-04-24T17:25:52Z-
dc.date.issued2009-
dc.identifier.issn1567-1739-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/105386-
dc.description.abstractWe fabricated carbon nanotube (CNT)-based biosensor with field effect transistor structure for detection of matrix metallopeptidase-9 (MMP-9) and S-100B. To minimize contact effects, the metal electrodes were passivated with SiOx film, and anti-MMP-9 and S-100B antibody were immobilized on the CNT surface using a chemical linker. When MMP-9 or S-100B antigen was added to bind anti-MMP-9 or S-100B antibody, the decrease in electrical conductance was observed. We have also investigated the dependence of MMP-9 and S-100B concentration on the conductance change. A linear relationship was found between the conductance and the concentration in semi-logarithm scale.-
dc.description.statementOfResponsibilityopen-
dc.format.extente270~e272-
dc.relation.isPartOfCURRENT APPLIED PHYSICS-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.titleCarbon nanotube-based biosensor for detection of matrix metallopeptidase-9 and S-100B-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Microbiology (미생물학)-
dc.contributor.googleauthorHyoung-Sub Lee-
dc.contributor.googleauthorJe-Seung Oh-
dc.contributor.googleauthorYoung-Wook Chang-
dc.contributor.googleauthorYoon-Jung Park-
dc.contributor.googleauthorJeon-Soo Shin-
dc.contributor.googleauthorKyung-Hwa Yoo-
dc.identifier.doi10.1016/j.cap.2009.07.003-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA02144-
dc.relation.journalcodeJ00659-
dc.identifier.eissn1878-1675-
dc.identifier.urlhttp://www.sciencedirect.com/science/article/pii/S1567173909003514-
dc.subject.keywordCNT–FET-
dc.subject.keywordBiosensor-
dc.subject.keywordMMP-9-
dc.subject.keywordS-100B-
dc.contributor.alternativeNameShin, Jeon Soo-
dc.contributor.affiliatedAuthorShin, Jeon Soo-
dc.citation.volume9-
dc.citation.number4 suppl-
dc.citation.startPage270-
dc.citation.endPage272-
dc.identifier.bibliographicCitationCURRENT APPLIED PHYSICS, Vol.9(4 suppl) : 270-272, 2009-
dc.identifier.rimsid51652-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Microbiology (미생물학교실) > 1. Journal Papers

qrcode