2 702

Cited 9 times in

Comparison of multi-echo and single-echo gradient-recalled echo sequences for SPIO-enhanced liver MRI at 3 T.

Authors
 J.S. Choi  ;  M.-J. Kim  ;  J.H. Kim  ;  J.-Y. Choi  ;  Y.E. Chung  ;  M.-S. Park  ;  K.W. Kim 
Citation
 CLINICAL RADIOLOGY, Vol.65(11) : 916-923, 2010 
Journal Title
CLINICAL RADIOLOGY
ISSN
 0009-9260 
Issue Date
2010
MeSH
Adult ; Aged ; Artifacts ; Carcinoma, Hepatocellular/diagnosis* ; Carcinoma, Hepatocellular/pathology ; Contrast Media* ; Female ; Ferrosoferric Oxide* ; Humans ; LiverNeoplasms/diagnosis* ; LiverNeoplasms/pathology ; Magnetic Resonance Imaging/instrumentation ; Magnetic Resonance Imaging/methods* ; Male ; Middle Aged ; Neoplasm Staging ; Reproducibility of Results ; Sensitivity and Specificity
Abstract
AIM: To assess the utility of a T2*-weighted, multi-echo data imaging combination sequenced on superparamagnetic iron oxide (SPIO)-enhanced liver magnetic resonance imaging (MRI) using a 3 T system.

MATERIALS AND METHODS: Fifty patients underwent SPIO-enhanced MRI at 3 T using T2*-weighted, single-echo, gradient-recalled echo (GRE) sequences [fast imaging with steady precession; repetition time (TR)/echo time (TE), 126 ms/9 ms; flip angle, 30°] and multi-echo GRE (multi-echo data image combination) sequences (TR/TE, 186 ms/9 ms; flip angle, 30°). Three radiologists independently reviewed the images in a random order. The sensitivity and accuracy for the detection of focal hepatic lesions (a total of 76 lesions in 33 patients; 48 solid lesions, 28 non-solid lesions) were compared by analysing the area under the receiver operating characteristic curves. Image artefacts (flow artefacts, susceptibility artefacts, dielectric artefacts, and motion artefacts), lesion conspicuity, and overall image quality were evaluated according to a four-point scale: 1, poor; 2, fair; 3, good; 4, excellent. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the lesions were compared.

RESULTS: Image artefacts were more frequent with single-echo GRE (p<0.05). The mean scale of image quality assessment for flow, susceptibility, dielectric, and motion artefacts were 2.76, 3.13, 3.42, and 2.89 with single-echo, respectively, compared with 3.47, 3.43, 3.47, and 3.39, respectively, with multi-echo GRE. There was no significant difference in lesion conspicuity between single-echo (3.15) and multi-echo (3.30) GRE sequences. The overall image quality was significantly (p<0.05) better with multi-echo (3.37) than with single-echo GRE (2.89). The mean SNR and CNR of the lesions were significantly (p<0.05) higher on multi-echo (79±23 and 128±59, respectively) images than on single-echo (38±11 and 102±44, respectively) images. Lesion detection accuracy and sensitivity were not significantly different between the two sequences. Mean accuracies and sensitivities were 0.864 and 0.785 for single-echo and 0.847 and 0.785 for multi-echo GRE, respectively.

CONCLUSION: At 3 T, the T2*-weighted, multi-echo data image combination sequence performs comparably to the T2*-weighted, single-echo GRE sequence for SPIO-enhanced MRI with good overall image quality and a decrease in undesired artefacts.
Full Text
http://www.sciencedirect.com/science/article/pii/S0009926010002886
DOI
10.1016/j.crad.2010.07.003
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiology (영상의학교실) > 1. Journal Papers
Yonsei Authors
Kim, Ki Whang(김기황)
Kim, Myeong Jin(김명진) ORCID logo https://orcid.org/0000-0001-7949-5402
Kim, Joo Hee(김주희) ORCID logo https://orcid.org/0000-0001-5383-3602
Park, Mi-Suk(박미숙) ORCID logo https://orcid.org/0000-0001-5817-2444
Chung, Yong Eun(정용은) ORCID logo https://orcid.org/0000-0003-0811-9578
Choi, Ji Soo(최지수)
Choi, Jin Young(최진영) ORCID logo https://orcid.org/0000-0002-9025-6274
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/101795
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links