590 894

Cited 24 times in

Evaluation of Optical Quality Parameters and Ocular Aberrations in Multifocal Intraocular Lens Implanted Eyes

DC Field Value Language
dc.contributor.author김응권-
dc.contributor.author김태임-
dc.contributor.author안지민-
dc.contributor.author이훈-
dc.date.accessioned2015-01-06T17:31:52Z-
dc.date.available2015-01-06T17:31:52Z-
dc.date.issued2014-
dc.identifier.issn0513-5796-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/100152-
dc.description.abstractPURPOSE: We investigated the correlations between optical quality parameters obtained from the double-pass system and ocular aberrations obtained from the ray-tracing aberrometer in multifocal intraocular lens (IOL) implanted eyes. MATERIALS AND METHODS: Twenty eyes from 20 patients were enrolled in this study. Modulation transfer function cutoff frequency, The Strehl ratio, objective scatter index, and objective pseudo-accommodation obtained from the double-pass system were compared with root mean square (RMS) total aberration, RMS higher-order aberration, and spherical aberration obtained from the ray-tracing aberrometer. Additionally, parameters of the double-pass system and ray-tracing aberrometer were compared with manifested refraction values and subjective visual acuity, respectively. RESULTS: There was no statistically significant correlation between optical quality parameters obtained from the double-pass system and ocular aberrations, except between the Strehl ratio and RMS total aberration (r=-0.566, p=0.018). No significant correlations were found between the parameters of both devices, and manifested refraction values or subjective visual acuity. CONCLUSION: Optical quality parameters, especially the Strehl ratio, in multifocal IOL implanted eyes were affected by RMS total aberration. Further studies based on accurate measurements of ocular aberrations and additional optical quality parameters are needed to delineate relationships between optical quality parameters and ocular aberrations in multifocal IOL implanted eyes.-
dc.description.statementOfResponsibilityopen-
dc.format.extent1413~1420-
dc.relation.isPartOfYONSEI MEDICAL JOURNAL-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAdult-
dc.subject.MESHAged-
dc.subject.MESHCataract Extraction-
dc.subject.MESHFemale-
dc.subject.MESHHumans-
dc.subject.MESHLens Implantation, Intraocular-
dc.subject.MESHLenses, Intraocular*-
dc.subject.MESHMale-
dc.subject.MESHMiddle Aged-
dc.subject.MESHRefraction, Ocular*-
dc.subject.MESHVisual Acuity*-
dc.titleEvaluation of Optical Quality Parameters and Ocular Aberrations in Multifocal Intraocular Lens Implanted Eyes-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Ophthalmology (안과학)-
dc.contributor.googleauthorHun Lee-
dc.contributor.googleauthorKwanghyun Lee-
dc.contributor.googleauthorJi Min Ahn-
dc.contributor.googleauthorEung Kweon Kim-
dc.contributor.googleauthorBradford Sgrignoli-
dc.contributor.googleauthorTae-im Kim-
dc.identifier.doi10.3349/ymj.2014.55.5.1413-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA00831-
dc.contributor.localIdA01080-
dc.contributor.localIdA02263-
dc.contributor.localIdA03344-
dc.relation.journalcodeJ02813-
dc.identifier.eissn1976-2437-
dc.identifier.pmid25048505-
dc.subject.keywordDouble-pass system-
dc.subject.keywordcataract surgery-
dc.subject.keywordmultifocal intraocular lens-
dc.subject.keywordoptical quality-
dc.subject.keywordray-tracing aberrometer-
dc.contributor.alternativeNameKim, Eung Kweon-
dc.contributor.alternativeNameKim, Tae Im-
dc.contributor.alternativeNameAhn, Ji Min-
dc.contributor.alternativeNameLee, Hun-
dc.contributor.affiliatedAuthorKim, Eung Kweon-
dc.contributor.affiliatedAuthorKim, Tae Im-
dc.contributor.affiliatedAuthorAhn, Ji Min-
dc.contributor.affiliatedAuthorLee, Hun-
dc.citation.volume55-
dc.citation.number5-
dc.citation.startPage1413-
dc.citation.endPage1420-
dc.identifier.bibliographicCitationYONSEI MEDICAL JOURNAL, Vol.55(5) : 1413-1420, 2014-
dc.identifier.rimsid51711-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Ophthalmology (안과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.